INSTALLATION &
OPERATION MANUAL
C24GA SERIES
GAS CONVECTION
STEAMERS
MODELS
C24GA6
C24GA10
ML-136021
ML-136022
Models manufactured after June 2006
C24GA6
C24GA10
ML-136056
ML-136057
For additional information on Vulcan-Hart or to locate an authorized parts
VULCAN-HART
3600 NORTH POINT BLVD.
BALTIMORE, MD 21222
DIVISION OF ITW FOOD EQUIPMENT GROUP, LLC
WWW.VULCANHART.COM
F-35423 Rev B. (10-07)
C24GA SERIES GAS CONVECTION STEAMERS
INTRODUCTION
GENERAL
INSTALLATION
Vulcan convection steamers are produced
with quality workmanship and material. Proper
installation, usage and maintenance will result
in many years of satisfactory performance.
INSTALLER: A manometer (digital or incline
tube) capable of reading pressure in 0.01"
W.C. is required to install this steamer. Failure
to set blower air and gas pressure correctly
will result in burner and lighting failure.
It is suggested that you thoroughly read this
entire manual and carefully follow all of the
instructions provided.
Before installing, verify that the type of gas
(natural or propane) and the electrical supply
required agree with the specifications on the
data plate located on the left edge of the
tabletop. If the supply and equipment
requirements do not agree, do not proceed
with the installation. Contact your dealer or
Vulcan-Hart immediately.
Model C24GA6 can accommodate three
21/2" deep (64 mm) steam pans per
compartment. Model C24GA10 can
accommodate five 21/2" deep (64 mm) steam
pans per compartment.
The C24GA6 and C24GA10 gas-fired
convection steamers are designed for cooking
vegetables, eggs, and other foods, in
commercial kitchens. Each compartment has
a 0 to 60 minute timer. (The buzzer requires
manual shutoff.) The steamers are equipped
with a cabinet base for floor installation.
INSTALLATION CODES
AND STANDARDS
The Vulcan steamer must be installed in
accordance with:
In the United States of America:
1. State and local codes.
C24GA6
C24GA10
Compartments
2
2
2. National Fuel Gas Code, ANSI-Z223.1/
NFPA #54 (latest edition). Copies may be
obtained from The American Gas
Association Accredited Standards
CommitteeZ223, @400N. CapitalSt. NW,
Washington, DC 20001, or the Secretary
Standards Council, NFPA, 1 Batterymarch
Park Quincy, MA 02169-7471.
Total Number of
21/2" (64 mm)
Deep Pans
6
10
Gas Rating
125,000
BTU/hr.
125,000
BTU/hr.
UNPACKING
3. NFPA Standard # 96 Vapor Removal from
Cooking Equipment, latest edition,
available from the National Fire Protection
Association, Batterymarch Park, Quincy,
MA 02269.
This steamer was inspected and tested before
leaving the factory. The transportation
company assumes full responsibility for safe
delivery upon acceptance of the shipment.
4. In the Commonwealth of Massachusetts all
gas appliances vented through a ventilation
hood or exhaust system equipped with a
damper or with a power means of exhaust
shall comply with 248 CMR.
Immediately after unpacking, check for
possible shipping damage. If steamer damage
is found, save the packaging material and
contact the carrier within 15 days of delivery.
— 3 —
C24GA SERIES GAS CONVECTION STEAMERS
In Canada:
An exhaust system should be located directly
above the steamer to exhaust steam, flue
exhaust and heat generated by the steamer.
1. Local codes.
2. CAN/CSA-B149.1 Natural Gas Installation
(latest edition).
Do not locate the steamer directly over a
drain.
3. CAN/CSA-B149.2PropaneInstallationCode
(latest edition), available from the Canadian
Gas Association, 178 Rexdale Blvd.,
Etobicoke, Ontario, Canada M9W 1R3.
LEVELING AND ANCHORING
Position the steamer in its final installed
location. Place a level on the horizontal area
of the cabinet. Adjust the feet to level the
steamer in both the left-to-right and front-to-
rear directions.
LOCATION - GAS STEAMERS
The equipment area must be kept free and
clear of combustible substances.
Steamers should be elevated in the front just
The recommended clearance for proper
operation is 36" (914 mm) at the front. The
required clearance from combustible or non-
combustible construction is 0" at the sides
and back. The recommended clearance for
service access is 18" (457 mm) at the sides
and 6" (152 mm) from the back.
1
1
enough, about /16" to /8" (2 to 3mm) to give
proper draining. Do this by rotating the
adjustable feet in the proper direction 1 to 1½
turns after leveling. Check drainage in the
steamer compartments by pouring a small
amount of water in the compartment. All the
water should drain.
Make sure there is an adequate supply of air
in the room to replace air taken out by the
ventilating system. If you have any questions,
contact the ventilation system installer.
The rear feet have holes in the flanges for
anchor bolts.
— 4 —
C24GA SERIES GAS CONVECTION STEAMERS
Water Supply Connection
PLUMBING CONNECTIONS
Plumbing connections
must comply with applicable sanitary,
safety and plumbing codes.
Connect the treated cold water supply line to
3
the /8" NPT inlet at the rear of the steamer.
Connect the untreated cold water supply line
to the 1/8" NPT, also at the rear of the steamer.
Water Requirements
Note: Models manufactured after June 2006
may have ¾" hose connections.
Proper water quality can improve the taste of
the food prepared in the steamer, reduce
liming in the steam generator and extend
equipment life. Local water conditions vary
from one location to another. Ask your
municipal water supplier for details about your
local water supply prior to installation.
A water filter system is recommended for the
water supply line going to the treated water inlet
of your steamer. Follow the recommendations
for use and installation instructions shipped
with the water filter. If a water filter is not
installed, the steamer or steam generator
warranty will be limited.
Presence of sediment, silica, excess chlorides
or other dissolved solids may lead to a
recommendation for alternate form(s) of water
treatment.TestthewaterwithaTDSmeterorthe
teststripincludedwiththesteamer.Otherfactors
affecting steam generation are iron content,
amount of chloridation and dissolved gases.
Filter System
If you decide to not install a scale reducing
filter system designed for steam equipment
or use another manufacturer’s system other
than recommended by Vulcan Hart, please
use these guide lines.
Water Treatment
•
If you are going to delime the unit with a
deliming agent recommended for a
pressure steam boiler and stainless steel
generators and you are on city or treated
well water, you still must have a carbon
block filter installed and maintained.
Carbon block filters remove the chlorine
and chloramines disinfectants from the
water. Chlorine and chloramines will erode
the boiler or steam generator and will
result in a vessel failure which is not
covered under warranty.
A local water treatment specialist should be
consulted before installation of steam
generating equipment.
Supply Pressure
Hardness*
20 - 60 psig
less than 3 grains
less than 13 ppm
less than 4.0 ppm
Silica
Total Chlorine
PH range
7 - 8
Undissolved Solids
less than 5
microns
•
Water feed lines to the steamer must be
flushed before final connection. Particles
in the water could build up in the water and
steam valves or clog tubing and
components that maintain the water level
and pressure in the boiler or steam
generator. If the water supply is not free of
sediment or cloudy after several minutes
of flushing, a sediment filter must be
installed before use.
*17.1 ppm = 1 grain of hardness
If the water supply fails to meet these
standards, it will be necessary to install a
water conditioner on the generator water feed.
The use of strainers or filters will not remove
minerals from the water.
•
If you have purchased water filter system
from Vulcan Hart, please follow the
— 5 —
C24GA SERIES GAS CONVECTION STEAMERS
instructions provided with the filter system.
At the time of installation you must register
filterreg or use the reply card supplied
with your unit. You will need to register
yoursteamerateachfilterchangetoinsure
your standard and extended warranty is
maintained.
GAS SUPPLY CONNECTION
All gas supply connections and any pipe joint
compound used must be resistant to the action
of propane gas. A ¾" NPT minimum inside
diameter gas supply line is required. If quick
disconnect devices are used, make sure it is
sized properly for data plate BTU/hr. rating.
Refer to quick connect supplier’s data sheet.
Codes require that a manual gas shutoff valve
be installed in the gas line ahead of the
steamer.
Drain Connection
The1½"NPTthreadedfittingonthecondenser
box must be extended a minimum of 12" (305
mm) - maximum of 72" (1829 mm) away from
steamer base, to an open air gap type drain.
Do not reduce the 1 ½" NPT drain piping
throughout its length. Provide a suitable floor
sink with a minimum depth of 12" (305 mm).
The floor sink is NOT to be directly under the
steamer and should be at a distance so that
steam vapors will not enter the steamer from
underneath. The drain should slope down
away from the steamer ¼" for every foot of
drain pipe length. The drain pipe should be
either iron or copper. DO NOT use PVC pipe;
PVC pipe may lose its rigidity or glue may fail.
The gas line must be capable of delivering gas
to the generator without excessive pressure
drop at the minimum rate specified on the
rating plate.
Check blower air pressure at gas manifold
pressure tap by shutting off the gas valve. Air
pressure at cold start-up should be 0.35" W.C.
(0.09 kPa) (cold condition). After 15 minutes,
air pressure should be between 0.40" W.C.
(0.1 kPa) and 0.50" W.C. (0.13 kPa) (hot
condition). Turn the air pressure adjust screw
clockwise to increase pressure and
counterclockwise to reduce pressure.
In order to avoid any back pressure in the
steamer, do not connect solidly to any drain
connection.
Gas Input:
Natural:
¾" NPT
_
5" 10.5" W.C.
_
Propane:
11" 13" W.C.
Temperatures in the generator can briefly
reach as high as 212°F (l00°C). Local codes
may require that the temperature of drain
water be no greater than 140°F (60°C). At the
end of the day, when purging the generators,
some provision for lowering the water
temperature must be provided by the user or
installer to meet this code requirement.
Inadequate gas supply could result in burner
noise and poor burner performance.
Refer to the instruction manual supplied with
the machine for INSTALLATION CODES AND
STANDARDS and GAS CONNECTION
information.
— 6 —
C24GA SERIES GAS CONVECTION STEAMERS
connector beyond a U shape. Flexing
the gas connector as described will
restrict gas flow or may damage the
connector.
Changing a flexible gas connector may raise
the BTU/hr. flow capacity enough to allow the
machine to operate within its design
specifications. (i.e. Removing the quick
disconnect fitting, installing a shorter gas
connector or installing a larger diameter gas
connector.)
An alternative may be to move the equipment
to a different gas supply location in the kitchen.
(i.e. Closer to the main supply into the kitchen
or away from other equipment with high
BTU/hr. input requirements.)
Air˚Pressure˚
Adjust˚Screw
On˚Side˚of˚
Drip˚Cover
Figure 1
The proper sizing and installation of the gas
connection is important for the machine to
operate within its design specifications. In
some installations, the gas supply may not be
sufficientenoughtoallowallthegasequipment
to operate properly at peak loads; or when
other equipment with a high BTU/hr. input
requirement is operating. The connection to
the machine becomes even more important in
this type of location.
Flexible gas connectors with quick disconnect
orswivelfittings(whenused)andgasconnectors
beyond the length necessary will reduce the
BTU/hr. flow capacity to the machine.
Note: Do not use corrugated stainless steel
tubing for commercial gas equipment
supply connections.
Note: A straight gas connection is the ideal
condition for the rated BTU/hr. flow
capacity of the connector. If a straight
connection is not possible and a
flexible gas connector is used, do not
twist, kink or excessively flex the
Figure 3
The generator is equipped with a factory-
preset pressure regulator. Natural gas
pressure regulators are preset for 2.5" W.C.
(0.62 kPa). Propane gas pressure regulators
— 7 —
C24GA SERIES GAS CONVECTION STEAMERS
Gas Connection Data
1, 2
FLEXIBLE GAS CONNECTORS BTU/hr. FLOW CAPACITY
3
3
LENGTH
LENGTH
End Fittings - Both Threaded
End Fittings - (1) Quick Disconnect
& (1) Threaded
ID
½"
¾"
1"
36"
48"
60"
72"
36"
48"
60"
72"
77,000
68,000
60,000
55,000
120,000 106,000
93,000
86,000
218,000 180,000 158,000 139,000 256,000 225,000 198,000 175,000
379,000 334,000 294,000 279,000 512,000 451,000 397,000 350,000
615,000 541,000 476,000 419,000 946,000 833,000 733,000 645,000
1¼"
1. Flow rating BTU/hr. 0.64 SP. GR @ 0.5 inch W.C. pressure drop.
2. BTU/hr. flow capacities are based on Dormont Mfg. Co. Supr-Safe gas line connectors and
are provided for reference. Additional quick disconnect fittings, swivels, or manual shut off
valves will reduce the BTU/hr. flow capacities listed in this table. If other flexible gas
connectors are used, check the manufacturer’s specifications for BTU/hr. flow capacities.
Supr-Safe is a registered trademark of the Dormont Manufacturing Company.
3. The maximum length for a flexible gas connector is 72" per National Fuel Code standards.
1, 2, 3
BLACK IRON PIPE BTU/hr. FLOW CAPACITY
Natural Gas
Nominal Inside Diameter of Pipe
Pipe Length
½"
¾"
1"
1¼"
1½"
2"
15'
30'
45'
60'
75'
90'
76,000
52,000
43,000
38,000
172,000
120,000
99,000
86,000
77,000
70,000
345,000
241,000
199,000
173,000
155,000
141,000
750,000
535,000
435,000
380,000
345,000
310,000
1,220,000
850,000
700,000
610,000
545,000
490,000
2,480,000
1,780,000
1,475,000
1,290,000
1,120,000
1,000,000
1. Flow rating BTU/hr. 0.64 SP. GR @ 0.3 inch W.C. pressure drop.
2. BTU/hr. flow capacities are based on Schedule 40 pipe, include a tolerance for pressure
losses in gas piping systems are provided for reference.
3. Count each 90° elbow as 3' of gas pipe for the purpose of calculating total pipe length.
— 8 —
C24GA SERIES GAS CONVECTION STEAMERS
are preset for 10" W.C. (2.46 kPa). No further
adjustment should be required. Check gas
pressures with a manometer at time of
installation to verify that they agree with the
pressures specified.
FLUE GAS EXHAUST
DO NOT obstruct the flow of flue gases from
the flue located on the rear of the steamer.
It is recommended that the flue gases be
vented to the outside of the building through
a ventilation system installed by qualified
personnel.
Prior to lighting, check all
joints in the gas supply line for leaks. Use
soap and water solution. Do not use an
open flame.
Informationontheconstructionandinstallation
of ventilating hoods may be obtained from
Vapor Removal from Cooking Equipment,
NFPA-96 (latest edition) available from the
National Fire Protection Association,
Batterymarch Park, Quincy, MA 02269.
A. Check all joints prior to the gas valve
(solenoid) before lighting unit.
B. Check all joints beyond gas valve
(solenoid) after unit is lit.
After piping has been checked for leaks, all
piping receiving gas should be fully purged to
remove air.
Testing the Gas Supply System
When the gas supply pressure exceeds
1
/
2
psig(3.45kPa),thesteameranditsindividual
manualgasshutoffvalvemustbedisconnected
from the gas supply piping system.
When the gas supply pressure is ½ psig
(3.45 kPa) or less, the steamer should be
isolated from the gas supply system by closing
its individual manual gas shutoff valve.
— 9 —
C24GA SERIES GAS CONVECTION STEAMERS
ELECTRICAL CONNECTION
START UP
Appliances equipped with
a flexible electric supply cord are pro-
vided with a three-prong grounding plug.
It is imperative that this plug be con-
nected into a properly grounded three-
prong receptacle. If the receptacle is not
the proper grounding type, contact an
electrician. Do not remove the grounding
prong from this plug.
The steamer and its parts
are hot. Use care when operating, clean-
ing or servicing the steamer.
The cooking compartment
contains live steam. Stay clear when
opening each door.
Once the steamer is installed and all
mechanical connections have been made,
thoroughly test the steamer before operation.
Electrical and grounding
connections must comply with the appli-
cable portions of the national electrical
code and/or other local electrical codes.
1. Check that proper water, drain, electrical
and gas connections have been made.
2. Turn on manual gas valve.
Refer to the data plate located on the left edge
of the tabletop and the electrical diagram
located behind the front panel on the base.
3. Press power switch to the on position. After
approximately 20 minutes the ready light
should come on, indicating that generator
has reached operating pressure.
ELECTRICAL DATA
4. With the door closed the ready light comes
on. Set the timer to the 5-minute position.
Open the door and observe that no steam is
entering the compartment and the ready
and cooking lights are off.
Volts
120
60
1
Hertz (Hz)
Phase
Machine Amps
3
5. Close the compartment door. The cooking
light should now be lit and steam should be
heard entering the compartment.
Minimum Circuit
Ampacity, Maximum
Protective Device
AMPS
15
6. Check the drain line to be sure that water
from the cold water condenser is flowing
through the drain line.
7. Openthecompartmentdoorandobservethat
steam supply to the compartment stops, and
that the ready light and cooking light turn off.
8. Close the compartment door and let the
cooking cycle finish. When the timer returns
to the 0 position, a buzzer will sound,
signaling the end of the cooking cycle and
the cooking light goes off. To silence the
buzzer,turnthedialtimertotheOFFposition.
9. Complete the above steps for each cooking
compartment.
10. To shutdown the steamer, press the power
switch to the off position and close the
manual gas shutoff valve. Leave the
compartment doors slightly open to allow
the inside to dry out.
— 10 —
C24GA SERIES GAS CONVECTION STEAMERS
OPERATION
The steamer and its parts
The steamer and its parts
are hot. Use care when operating, clean-
ing or servicing the steamer.
are hot. Use care when operating, clean-
ing or servicing the steamer.
Compartment Controls and Indicators
The cooking compartment
contains live steam. Stay clear when
opening each door.
ITEM
FUNCTION
Ready Light
(Green)
Indicates the steamer is ready
for the cooking cycle
LIGHTING AND SHUTDOWN
INSTRUCTIONS
Cooking Light Indicates the steamer is in the
(Red)
Timer
cooking phase
Set the desired cooking time.
Timer range is 0-60 minutes or
constant. Turn to the OFF
position to silence buzzer.
Lighting
1. Turnmanualgasshutoffvalvetoonposition.
2. Press power switch on. Steam will
generate in 20 minutes.
3. Ready light will light when compartment is
ready for cooking.
4. Load food and set timer to proper cook
time. Door must be closed.
Shutdown
1. Press power switch off.
2. Wait 5 minutes before relighting the
appliance (if required).
3. Turn manual gas shutoff valve to off
position.
4. Do not unplug or turn off power supply for
at least 20 minutes after power switch is
turned off.
5. Leave compartment door sightly open.
COMPARTMENT CONTROLS
The upper section of the steamer consists of
twocookingcompartments. Eachcompartment
functions independently with its own controls
(See Figure 4) and is a separate, sealed steam
chamber during the cooking operation.
Figure 4. Cabinet Controls
— 11 —
C24GA SERIES GAS CONVECTION STEAMERS
Refer to Steam Cooking with Vulcan Kettles
and Steamers for suggested cooking times.
Also refer to the Suggested Cooking Guideline
in this manual. Size, weight, pan loading and
product quality will affect cooking times and
should be adjusted to your own requirements.
3. The buzzer will sound when the cooking
cycleendsandsteamhasstoppedentering
the cooking compartment(s).
•
Turn the timer(s) to the OFF position
to silence the buzzer(s); remove the
cooked food.
•
The red cooking light will go off and
the green ready light will come on to
indicate the steamer is ready for the
next cooking cycle.
STARTUP PROCEDURE
1. Open manual gas shutoff valve and ensure
the steamer doors are closed.
2. Press power switch to the on position.
STEAMING
3. If Ready light fails to turn on in 20 minutes,
press power switch off and back on to
reset ignition system.
Each steaming compartment has its own
controls.
With the Ready light lit, the steamer is ready
for use.
PREHEATING
•
•
•
Place pans of food to be cooked into the
compartment and shut the door.
Preheat the cooking cavity when the steamer
is first used for the day or whenever the
compartment is cold. Keep the door closed
during the preheat cycle.
Set the timer to the desired cooking
time. Steaming begins.
•
When the green ready light comes on,
set the timer to 10 minutes to preheat
the compartment.
The cooking cycle may be interrupted at
any time by opening the compartment
door. Resume cooking by closing the door.
•
•
The red cooking light is lit.
•
When the buzzer sounds, the timed
steaming cycle has finished. Steaming
stops, the cooking light goes off. To
silence the buzzer, turn the timer OFF.
When the buzzer sounds, turn the timer
to the OFF position. The steamer is
ready to cook.
EXTENDED SHUTDOWN
OPERATING
To shut down for an extended period:
1. With the compartment(s) preheated and
the green ready light on, place pans of
food into the cooking compartment(s) and
shut the door(s).
1. Press power switch off.
2. Turn manual gas shutoff valve to off.
3. Clean the compartment(s).
2. Turn the timer(s) to the desired cooking
time.
4. After 20 minutes unplug steamer.
•
•
The cooking cycle will begin.
The cooking cycle and time may be
interrupted at any time by opening
the door. Close the door to resume
cooking.
— 12 —
C24GA SERIES GAS CONVECTION STEAMERS
Compartments
CLEANING
Wash the inside of the compartment with a
solution of warm water and non-chloride
detergent. Rinse with warm water.
Disconnect the electrical
power to the machine and follow lockout /
tagout procedures before cleaning.
Once a week, thoroughly clean the exposed
surfaces (sides, front, door and top) with a damp
cloth and polish with a clean cloth. To remove
discolorations, use a nonabrasive cleaner.
Cooking Compartment Drains
Keep compartment drains running freely.
Inspect compartment drains daily for
blockage. Remove any particles or debris
from the perforated strainer daily (or more
often if needed).
Door Gaskets
Clean the gasket sealing surface of the
compartment doors to remove food acids for
maximum gasket life. Do not use any solvents
or sharp instruments. Wash with a cloth
moistened in a solution of mild detergent and
warm water. Rinse with a fresh cloth
moistened with warm water to remove all
traces of detergent.
After cooking greasy foods or seafood, close
the doors and operate each compartment for
25 to 30 minutes to flush any residual grease
and oils down the compartment drain. Make a
solution of warm water and non-chloride
detergent and pour ½ gallon (1.9 liters) of it
down each compartment drain. Rinse by
pouring ½ gallon (1.9 liters) of hot water down
each compartment drain.
Wipe dry with a clean cloth. Never apply food
oils or petroleum lubricants directly to the
door gasket. Petroleum-based solvents and
lubricants will reduce gasket life.
Draining Generator
To prevent malfunction of controls and
clogging, it is essential to drain the generator
every day. This will flush out any accumulated
minerals from the feed water. It will also aid in
preventing internal scale buildup which would
interfere with proper generator operation.
Failure to drain the generator every day will
void the steamer warranty. The presence of
minerals in suspension is indicated by a murky
or milky condition in the first portion of the
water drained.
The water being
drained is hot and under pressure.
Use care when cleaning or servicing
the generator.
After the generator has been in operation, turn
the unit off with the power switch located on
bottom cooking cavity to drain the generator.
The generator will drain for approximately 15
minutes, removing sediment, scale and lime
buildup in the generator.
— 13 —
C24GA SERIES GAS CONVECTION STEAMERS
Avoid rubbing with steel pads, wire brushes or
scrapers that can leave iron deposits on
stainless steel. Instead, use plastic scouring
pads or soft cloths. For stubborn stains, use
products such as Cameo, Talc or Zud First
Impression. Always rub parallel to the polish
lines or with the grain.
LEAVE COMPARTMENT DOORS OPEN
Leave the compartment doors slightly open
when the steamer is not in use. When the
compartment is idle, never latch the door and
apply pressure to the door gasket. Leaving the
gasket under pressure can cause permanent
deformation and reduce gasket life.
Hard water will leave deposits that promote
rust on stainless steel. Treated water from
softeners or certain filters can eliminate these
mineral deposits. Other deposits from food or
lubrication must be properly removed by
cleaning. Use mild detergent and non-chloride
cleaners. Rinse thoroughly. Wipe dry. Where
appropriate, apply a polish recommended for
stainless steel (such as Benefit or Super
Sheen) for extra protection and luster.
GUIDELINES FOR MAINTAINING
STAINLESS STEEL SURFACES
There are four things that will break down
stainless steel and allow corrosion to
develop: 1) abrasion, 2) deposits, 3) water
and 4) chlorides.
— 14 —
C24GA SERIES GAS CONVECTION STEAMERS
MAINTENANCE
Draining Generator
The steamer and its parts
are hot. Use care when operating, clean-
ing or servicing the steamer.
At least once daily, turn the unit off with the
powerswitchlocatedonbottomcookingcavity,
to drain the generator.
Water Treatment System
Note: DO NOT remove the electric supply
A water treatment system is recommended for
steamers. Refer to your supplier’s manual for
normal maintenance procedures for proper
scale-free operation recommendations.
or the unit will not drain.
Door Gaskets
If the door gasket is leaking due to a nick or cut,
it must be replaced. Damage to the gasket
sealing surface will cause steam leakage.
Scale Related Maintenance
Periodic maintenance is necessary to keep
your generator clean and efficient. Initially, after
three months of steamer usage, it is
recommended that you have your Vulcan-Hart
authorizedservicerinspectthegenerator.Local
water conditions and steamer usage will
determine the frequency that this service must
Flue
Annually (at minimum), when the steamer is
cool, check theflueandclearany obstructions.
be repeated; however,
a
minimum
recommendation is once a year. This
maintenance is not covered by warranty.
— 15 —
C24GA SERIES GAS CONVECTION STEAMERS
COOKING CHART
The following table lists suggested cooking times and weights. These times, which will vary
depending on initial product temperature, size, shape, etc., are approximate and should be
adjusted to suit your operation.
PRODUCTS TO BE COOKED IN SOLID PANS
PRODUCT
TIMER SETTING
IN MINUTES
WEIGHT
PER PAN
Eggs, Scrambled
12
25
8 Dozen
2 lbs.
Rice, Long Grain (Cover with 4 cups water/lb.)
Pasta (Place perforated pan inside solid pan, cover
pasta with cold water
Spaghetti – Regular/Vermicelli
Macaroni - Shells/Elbows
Noodles - ½" Wide
12-15
15-18
12-15
15-18
4 lbs.
4 lbs.
4 lbs.
4 lbs.
Lasagna Noodles
Frozen Casseroles, Lasagna
Meat Loaf, 3-5 Lb. Each
35
40
Full Pan
15 lbs.
Beef
Ground Chuck
Sliced as Purchased
20-25
35-40
5
10 lbs.
10 lbs.
4 lbs.
Shrimp, Frozen, 10 Shrimp per Lb.
Beans
Baked
Refried
9
9
6
10 lb. Can
10 lb. Can
10 lb. Can
Canned Vegetables
Prunes, Dried
15
— 16 —
C24GA SERIES GAS CONVECTION STEAMERS
PRODUCTS TO BE COOKED IN PERFORATED PANS
PRODUCT
TIMER SETTING
IN MINUTES
WEIGHT
PER PAN
Clams
Frozen
Fresh
10-12
10-12
3 Dozen
3 Dozen
King Crab Frozen
Claws
Legs
4
4-6
2-½ Lbs.
2-½ Lbs.
10 lbs.
Lobster Tail, Frozen
6
5
Lobster, Live, 10" – 12"
Salmon Fillets, Frozen, 8 Oz. Ea
Scallops, Fresh
4 per pan
5
7-½ lbs.
3 lbs.
4
Scrod Fillets, Fresh
3.5
4 lbs.
Eggs
Hard Cooked
Soft Cooked
Soft Yoke for Caesar Salad
15
9-10
6-8
20
4 Dozen
4 Dozen
4 Dozen
Chicken Breasts, Legs, Thighs
15 lbs.
Turkey
Frozen Breasts (2)
Cut Lengthwise
90
95
6-7 lbs. ea.
20-25 lbs. ea.
Corned Beef
40-75
6-8 lbs.
Hot Dogs or Wieners
3
80-100 Count
Asparagus Spears
Frozen
Fresh
10-12
5
3 Dozen
5 lbs.
Beans
Green, 2" Cut, Frozen/Fresh
Lima, Frozen
Baby Lima, Frozen
6
8
5
5 lbs.
5 lbs.
5 lbs.
Broccoli
Spears, Frozen
Spears, Fresh
Flowerettes, Frozen
8
6
6
4 lbs.
5 lbs.
5 lbs.
5 lbs.
5 lbs.
Brussel Sprouts, Frozen
Cabbage, Fresh, 1/6 Cut
6
8
— 17 —
C24GA SERIES GAS CONVECTION STEAMERS
PRODUCTS TO BE COOKED IN PERFORATED PANS
PRODUCT
TIMER SETTING
IN MINUTES
WEIGHT
PER PAN
Carrots
Baby Whole, Frozen
Crinkle Cut, Frozen
Sliced, Fresh
8
7-8
11
7 lbs.
4 lbs.
9 lbs.
Cauliflower, Flowerettes
Frozen
Fresh
6
7-8
7
4 lbs.
5 lbs.
5 lbs.
Celery, 1" Diagonal Cut
Corn
Yellow Whole Kernel, Frozen
Cobbettes, Frozen
Corn On Cob, Fresh
5
8
5 lbs.
27 Ears
80 Ears
18 Ears
54 Ears
16-18
10-12
16-18
Peas, Green
6
5 lbs.
Potatoes, “Whole Russet”
55
10 lbs.
Spinach
Chopped, Frozen
Defrosted
Fresh Cut
17
5
3
6 lbs.
6 lbs.
2 lbs.
Squash, Acorn, Halves
Zucchini, Slices
25
8
10 Halves
10 lbs.
Frozen Mixed Vegetables
6-7
5 lbs.
Fruit, Blanch for Peeling
Grapefruit
Oranges
3
3
Pineapple, Whole for Cutting
4
COOKING HINTS
Where possible, spread food out evenly in pans. Do not allow food to protrude above pans, since
this will interfere with steam circulation between pans in the compartment.
Always preheat compartments for satisfactory results.
When time does not allow for defrosting of frozen vegetables, such as loose-pack peas, corn, diced
carrots, etc., they may be cooked at once provided just half of the suggested portions in the cooking
chart are used.
— 18 —
C24GA SERIES GAS CONVECTION STEAMERS
TROUBLESHOOTING
SYMPTOMS
POSSIBLE CAUSES
Gas supply is off
REMEDY
Unit not steaming
Turn on gas supply.
Power cord is unplugged
Power switch is off
Plug in power cord.
Press power switch on.
Turn on water supply.
Water supply is off
Burner control goes into 100%
lockout
Shut off the power, wait 5
minutes, then turn power back on
to restart ignition.
If symptom persists, contact your
Authorized Vulcan-Hart Servicer.
Door leaks
Damaged door gasket
Plugged drain or screen
Check door gasket for damage.
If adjustment is needed, contact
your Authorized Vulcan-Hart
Servicer.
Clear compartment cavity screen.
If symptom persists, contact your
Authorized Vulcan-Hart Servicer.
Water accumulates in
compartment
Drain clogged
Unclog drain.
Not leveled properly
Level per instructions in this
manual.
Water not being
supplied to generator
Water supply valve is off
Water pressure low
Turn valve on.
Check water supply pressure.
Water filter is plugged
Refer to water filter manual.
If symptom persists, contact your
Authorized Vulcan-Hart Servicer.
Steam is exiting from
under unit
Generator pressure is too high
Contact your Authorized Vulcan-
Hart Servicer.
SERVICE AND PARTS INFORMATION
To obtain service and parts information concerning this model, contact the Vulcan-Hart Service
Service and Parts depots).
When calling for service, the following information must be available: model number, serial number,
manufacture date (MD) and voltage.
— 19 —
C24GA SERIES GAS CONVECTION STEAMERS
F-35423 Rev B. (10-07)
— 20 —
PRINTED IN U.S.A.
|