Patton electronic Switch 03340D4 001 User Manual

CopperLink™ 1214E Series  
Extended Temperature  
Ethernet Extender  
Quick Start Guide  
Important—This is a Class A device and is intended for use in a light  
industrial environment. It is not intended nor approved for use in an  
industrial or residential environment.  
REGULATORY MODEL NUMBER: 03340D4-001  
Sales Office: +1 (301) 975-1000  
Part Number: 07MCL1214E-QS, Rev. C  
Technical Support: +1 (301) 975-1007  
Revised: July 24, 2014  
 
1.0 Configure the DIP Switches  
The CL1214E has eight DIP switches (S1) for configuring the unit for a wide variety of  
applications. Once the Cl1214E’s are properly installed, they should operate transpar-  
ently. No user settings required.  
Note Before applying power to the CL1214E, please review section 2.0,  
“Power up the CL1214E Series” on page 5 to verify that the unit is con-  
nected to the appropriate power source.  
1.1 Configuring the Hardware DIP Switches  
The DIP switches are externally accessible from the underside of the CL1214E.  
Figure 1 shows the orientation of the DIP switches in the ON and OFF positions.  
Figure 1. DIP switch orientation  
Configuring DIP Switch S1  
DIP Switch S1 is where you configure the CopperLink line. The following tables  
describe the configuration for the CL1214E.  
Table 1. S1 Summary  
Position  
Description  
S1-2  
S1-3  
S1-4  
S1-5  
S1-6  
Line Rate/Symmetry  
Line Rate/Symmetry  
Reserved  
SNR Margin  
Reserved  
CopperLink 1214E Series Quick Start Guide  
3
 
 
Table 1. S1 Summary  
Position  
Description  
S1-7  
S1-8  
Reserved  
Reserved  
Switch S1-1: Local/Remote Configuration  
Use Switch S1-1 to configure the unit as Remote or Local in the CL1214E.  
Table 2. Local/Remote Unit Configuration  
S1-1  
Setting  
ON  
CPE/Remote  
CO/Local  
OFF  
Switches S1-2 and S1-3: Symmetric/Asymmetric Operation  
Use Switches S1-2 and S1-3 to configure the CopperLink line rate type and operation.  
Table 3. Symmetric/Asymmetric Selection Chart  
S1-2  
S1-3  
Setting  
OFF  
OFF  
ON  
OFF  
ON  
High-Speed “Symmetric”  
High-Speed Asymmetric”  
OFF  
ON  
FastPath High-Speed Asymmetric”  
Long-Range Asymmetric”  
ON  
Switch S1-5: General Protection (Signal to Noise Ratio)  
Use Switch S1-5 to configure line noise protection.  
Table 4. Signal to Noise Ratio  
S1-5  
Setting  
ON  
6dB  
9dB  
OFF  
6dB: Original line noise protection with 6dB SNR  
9dB: Better line noise protection with SNR up to 9dB  
4
CopperLink 1214E Series Quick Start Guide  
 
2.0 Power up the CL1214E Series  
The CL1214E Series comes with an external AC power supply (see figure 2).  
Figure 2. Power Supply Installation  
2.1 Models with external AC adapter  
1. To connect the AC power supply, determine the positive lead and negative lead on  
the power adapter.  
2. Insert the positive lead into the opening on the terminal block labeled + and the  
negative lead into the opening on the terminal block labeled -.  
3. Tighten the screws on the block to secure the wires.  
The CL1214E Series powers up as soon as it is connected to an AC power source—  
there is no power switch.  
2.2 Power up indication  
Verify that the Power LED on the front panel (see figure 3) illuminates and remains lit.  
Figure 3. CL1214E front panel  
3.0 Connect the CopperLink interface  
1. Obtain single-twisted-pair cable with an RJ-45 plug connector at each end.  
CopperLink 1214E Series Quick Start Guide  
5
 
   
2. Plug one end of the cable into the RJ-45 socket (labeled Line) on the CL1214E.  
Verify that the other end of the cable is connected to the Line port on the other  
CL1214E and that the port is correctly configured.  
3. When a link is established, the Line Link LED will turn on.  
4.0 Connect the Ethernet port(s)  
The RJ-45 ports labeled Eth 0 through Eth 3 are the Auto-MDIX 10/100Base-T inter-  
face. These ports are designed to connect directly to a 10/100Base-T device or network.  
You may connect this port to a hub or PC using a straight through or crossover cable  
that is up to 328 ft (100 m) long.  
5.0 Additional information  
For detailed information about installing, configuring, and operating the CopperLink,  
refer to the CopperLink 1214E Series User Manual at www.patton.com/manuals/  
CL1214E-UM.pdf.  
A.0 Compliance Information  
A.1 Compliance  
EMC:  
EN55022, Class A  
EN55024  
Safety:  
IEC/EN60950-1, 2nd edition  
PSTN:  
This device is not intended nor approved for connection to the PSTN  
1.2 Radio and TV Interference (FCC Part 15)  
This equipment generates and uses radio frequency energy, and if not installed and  
used properly—that is, in strict accordance with the manufacturer's instructions—may  
cause interference to radio and television reception. This equipment has been tested  
and found to comply with the limits for a Class A computing device in accordance with  
the specifications in Subpart B of Part 15 of FCC rules, which are designed to provide  
reasonable protection from such interference in a commercial installation. However,  
there is no guarantee that interference will not occur in a particular installation. If the  
equipment causes interference to radio or television reception, which can be deter-  
mined by disconnecting the cables, try to correct the interference by one or more of the  
following measures: moving the computing equipment away from the receiver, re-ori-  
6
CopperLink 1214E Series Quick Start Guide  
 
enting the receiving antenna, and/or plugging the receiving equipment into a different  
AC outlet (such that the computing equipment and receiver are on different branches).  
A.3 CE Declaration of Conformity  
(See section A.4 “EG-Konformitätserklärung” for German version.)  
Product Description: CopperLink 1214E Series  
This equipment conforms to the requirements of Council Directive 1999/5/EC on the  
approximation of the laws of the member states relating to Radio and Telecommunica-  
tion Terminal Equipment and the mutual recognition of their conformity and the Direc-  
tive 2011/65/EC relating to RoHS compliance.  
The safety advice in the documentation accompanying the  
products shall be obeyed. The conformity to the above direc-  
tive is indicated by the CE sign on the device.  
The signed Declaration of Conformity can be downloaded from www.patton.com/certi-  
A.4 EG-Konformitätserklärung  
(see section A.3 “CE Declaration of Conformity” for English version)  
Produktbezeichnung: CopperLink 1214E Series  
Die bezeichneten Produkte stimmen in der von uns in Verkehr gebrachten Ausführung  
mit den Vorschriften folgender Richtlinie überein:  
R&TTE 1999/5/EG  
Richtlinie des europäischen Parlaments und des Rates zur Angleichung der  
Rechtsvorschriften der Mitgliedstaaten über Funkanlagen und  
Telekommunikations-Endeinrichtungen und die gegenseitige Anerkennung  
ihrer Konformität.  
Die Sicherheitshinweise in der mitgelieferten  
Produktdokumentation sind zu beachten. Die Konformität mit  
der oben erwähnten Richtlinie wird durch das CE-Zeichen  
auf dem Gerät bestätigt.  
Die unterzeichnete Konformitätserklärung kann heruntergeladen werden von:  
A.5 Authorized European Representative  
D R M Green  
European Compliance Services Ltd  
Greyfriars Court  
Paradise Square  
Oxford, OX1 1BE, UK  
CopperLink 1214E Series Quick Start Guide  
7
 
   
Copyright statement  
Copyright © 2013, Patton Electronics Company. All rights reserved.  
The information in this document is subject to change without notice. Patton Electron-  
ics assumes no liability for errors that may appear in this document.  
Trademarks statement  
The term CopperLink is a trademark of Patton Electronics Company. All other trade-  
marks presented in this document are the property of their respective owners.  
Patton support headquarters in the USA  
Online support: Available at www.patton.com  
E-mail support: E-mail sent to [email protected] will be answered within 1 busi-  
ness day  
Telephone support: Standard telephone support is available five days a week—from  
8:00 am to 5:00 pm EST (1300 to 2200 UTC/GMT)—by calling +1 (301) 975-1007  
Support via VoIP: Contact Patton free of charge by using a VoIP ISP phone to call  
Fax: +1 (301) 869-9293  
Alternate Patton support for Europe, Middle East, and Africa  
(EMEA)  
Telephone support: Standard telephone support is available five days a week—from  
8:00 am to 5:00 pm CET (0900 to 1800 UTC/GMT)—by calling +41 (0)31 985 25 55  
Fax: +41 (0)31 985 25 26  
Note For additional service and support information, refer to the “Contacting  
Patton for assistance” chapter of the CopperLink 1214E Series User  
Manual available online at www.patton.com/manuals/CL1214E-  
UM.pdf.  
Warranty, Trademark, & Compliance Information  
For warranty, trademark and compliance information, refer to the CopperLink 1214E  
Series User Manual available online at www.patton.com/manuals/CL1214E-UM.pdf.  
8
CopperLink 1214E Series Quick Start Guide  
 

Miele Vacuum Cleaner S4212 User Manual
Miele Ventilation Hood DA 398 5 User Manual
MTX Audio Speaker 620WE User Manual
Muratec All in One Printer MFX 1350D User Manual
NewAir Humidifier AU 200E User Manual
New Holland Lawn Mower T6020 User Manual
North Star Portable Generator M165912I3 User Manual
Panasonic Cell Phone KX TDA User Manual
Panasonic Personal Computer CF T7 User Manual
Parkside Heat Gun PHLG 600 User Manual