Omron Healthcare Blood Pressure Monitor BP652 User Manual

INSTRUCTION MANUAL  
7 series  
Automatic Wrist Blood  
Pressure Monitor  
Model BP652  
 
INTRODUCTION  
Thank you for purchasing the OMRON® BP652 IntelliSense® Automatic Wrist Blood  
Pressure Monitor.  
Fill in for future reference.  
DATE PURCHASED:__________________  
SERIAL NUIMBER:___________________  
s 3TAPLE YOUR PURCHASE RECEIPT HERE  
s 2EGISTER YOUR PRODUCT ONꢀLINE AT  
WWWꢁREGISTERꢀOMRONꢁCOM  
The monitor is compact and easy-to-use at home, at work, and during travel. Perfect for  
people who frequently monitor their own blood pressure.  
Your new digital blood pressure monitor uses the oscillometric method of blood pres-  
sure measurement. This means the monitor detects your blood’s movement through  
your brachial artery and converts the movements into a digital reading. An oscillomet-  
ric monitor does not need a stethoscope so the monitor is simple to use.  
Clinical research has proven a direct relationship between blood pressure in the wrist  
DQGꢀEORRGꢀSUHVVXUHꢀLQꢀWKHꢀDUPꢁꢀ&KDQJHVꢀLQꢀZULVWꢀEORRGꢀSUHVVXUHꢀUHÀHFWꢀFKDQJHVꢀLQꢀDUPꢀ  
blood pressure because the arteries in the wrist and the arm are close to each other.  
Frequently measuring the blood pressure in your wrist will provide your physician with  
an accurate indication of changes in your blood pressure.  
The BP652 comes with the following components:  
‡ꢀ0RQLWRUꢀ‡ꢀ6WRUDJHꢀ&DVHꢀ‡ꢀꢂꢀ³$$$´ꢀ$ONDOLQHꢀ%DWWHULHV  
‡ꢀ,QVWUXFWLRQꢀ0DQXDOꢀSULQWHGꢀLQꢀ(QJOLVKꢀDQGꢀ6SDQLVKꢀ‡ꢀ4XLFNꢀ6WDUWꢀ*XLGH  
The BP652 IntelliSense® Automatic Wrist Blood Pressure Monitor is intended for home use.  
SAVE THESE INSTRUCTIONS  
Download from Www.Somanuals.com3. All Manuals Search And Download.  
SAFETY INFORMATION  
To assure the correct use of the product, basic safety measures should always be  
followed including the warnings and cautions listed in this instruction manual.  
SAFETY SYMBOLS USED IN THIS INSTRUCTION MANUAL  
Indicates a potentially hazardous situation which, if not avoided,  
could result in death or serious injury.  
WARNING  
Indicates a potentially hazardous situation which, if not avoided,  
may result in minor or moderate injury to the user or patient or  
damage to the equipment or other property.  
CAUTION  
OPERATING THE DEVICE  
ꢀ&RQWDFWꢀ\RXUꢀSK\VLFLDQꢀIRUꢀVSHFL¿FꢀLQIRUPDWLRQꢀDERXWꢀ\RXUꢀEORRGꢀSUHVVXUHꢁꢀ  
Self-diagnosis and treatment using measured results may be dangerous. Follow the  
instructions of your physician or licensed healthcare provider.  
DO NOT adjust medication based on measurement results from this blood pressure  
monitor. Take medication as prescribed by your physician. Only a physician is  
TXDOL¿HGꢀWRꢀGLDJQRVHꢀDQGꢀWUHDWꢀ+LJKꢀ%ORRGꢀ3UHVVXUHꢁ  
The monitor is not intended to be a diagnostic device.  
ꢀ,IꢀEDWWHU\ꢀÀXLGꢀVKRXOGꢀJHWꢀLQꢀ\RXUꢀH\HVꢃꢀLPPHGLDWHO\ꢀULQVHꢀZLWKꢀSOHQW\ꢀRIꢀFOHDQꢀ  
water. Contact a physician immediately.  
If you have a condition that may compromise circulation, you may get an inaccurate  
reading with this device. Consult your physician before using this device.  
Read all of the information in the instruction manual and any other literature in the  
box before operating the unit.  
This device is intended for use in measuring blood pressure and pulse rate in the  
adult population. Do not use this device on infants or persons who cannot express  
their intentions.  
Operate the device only as intended. Do not use the device for any other purpose.  
Dispose of the device, components and optional accessories according to applicable  
local regulations. Unlawful disposal may cause environmental pollution.  
 
4
SAFETY INFORMATION  
Do not use a cellular phone near the device. It may result in an operational failure.  
Use only Omron authorized parts and accessories. Parts and accessories not  
approved for use with the device may damage the unit.  
ꢀ8VHꢀRQO\ꢀꢄꢁꢅꢀ9ꢀ³$$$´ꢀDONDOLQHꢀEDWWHULHVꢀZLWKꢀWKLVꢀGHYLFHꢁꢀ'RꢀQRWꢀXVHꢀRWKHUꢀW\SHVꢀRIꢀ  
batteries. This may damage the unit.  
CARE AND MAINTENANCE  
ꢀ'RꢀQRWꢀVXEMHFWꢀWKHꢀPRQLWRUꢀWRꢀVWURQJꢀVKRFNVꢃꢀVXFKꢀDVꢀGURSSLQJꢀWKHꢀXQLWꢀRQꢀWKHꢀÀRRUꢁ  
Do not submerge the device or any of the components in water.  
Store the device and the components in a clean, safe location.  
ꢀ&KDQJHVꢀRUꢀPRGL¿FDWLRQꢀQRWꢀDSSURYHGꢀE\ꢀWKHꢀPDQXIDFWXUHUꢀZLOOꢀYRLGꢀWKHꢀXVHUꢀ  
warranty. Do not disassemble or attempt to repair the unit or components.  
Download from Www.Somanuals.com5. All Manuals Search And Download.  
BEFORE TAKING A MEASUREMENT  
To ensure a reliable reading follow these recommendations:  
1. Avoid eating, drinking alcohol, smoking, exercising, and bathing for 30 minutes  
before taking a measurement. Rest for at least 15 minutes before taking the  
measurement.  
2. Stress raises blood pressure. Avoid taking measurements during stressful times.  
3. The cuff can be applied to your left or right wrist.  
4. Measurements should be taken in a quiet place.  
5. Position the unit at heart level throughout the measurement.  
6. Remain still and do not talk during the measurement.  
7. Wait 2-3 minutes between measurements. The wait time allows the arteries to return  
to the condition prior to taking the blood pressure measurement. You may need to  
increase the wait time depending on your individual physiological characteristics.  
8. Keep a record of your blood pressure and pulse readings for your physician. A  
single measurement does not provide an accurate indication of your true blood  
pressure. You need to take and record several readings over a period of time. Try to  
measure your blood pressure at the same time each day for consistency.  
 
6
KNOW YOUR UNIT  
Main Unit:  
Display  
Wrist cuff  
Memory (MEM)  
button  
START/STOP button  
Date/Time setting  
) button  
User ID selection  
switch  
(
SET button  
Date/Time setting  
) button  
(
Battery compartment  
Components:  
INSTRUCTION MANUAL  
7
series  
Automatic Wrist Blood  
Pressure Monitor  
Model BP652  
5329415-9A  
INTRODUCTION  
®
®
Thank you for purchasing the OMRON BP652 IntelliSense Automatic Wrist Blood  
Pressure Monitor  
.
Fill in for future reference.  
DATE PURCHASED: __________________  
SERIAL NUMBER: ____________________  
s
3TAPLE YouPURHASe rEEIPT HERE  
2 AAAAlkaline Batteries  
Instruction  
Manual  
Quick Start  
Guide  
Download from Www.Somanuals.com7. All Manuals Search And Download.  
UNIT DISPLAY  
Positioning indicator  
Diastolic blood pressure  
Memory symbol  
(Displayed when viewing  
values stored in memory)  
Systolic blood pressure  
Deflation symbol  
Average value symbol  
(Refer toUsing the  
Memory Function.)  
Irregular heartbeat symbol  
Movement error symbol  
(Displayed if you move  
your body during the  
measurement)  
Blood pressure level  
indicator  
Buzzer symbol  
User ID symbol (A or B)  
(If ³GUEST´ is selected, A  
or B will not be displayed.)  
Date/Time display  
Heartbeat symbol  
(Flashes during  
measurement)  
Wrist symbol  
Battery low symbol  
Pulse display  
 
8
DISPLAY SYMBOLS  
IRREGULAR HEARTBEAT SYMBOL (  
)
When the monitor detects an irregular rhythm two or more times during the  
measurement, the Irregular Heartbeat Symbol ( ) will appear on the display with the  
measurement values.  
$QꢀLUUHJXODUꢀKHDUWEHDWꢀUK\WKPꢀLVꢀGH¿QHGꢀDVꢀDꢀ  
rhythm that varies by less than 25% from the  
average rhythm or 25% more than the average  
rhythm detected while the monitor is measuring  
the systolic and diastolic blood pressure.  
.ORMAL (EARTBEAT  
Pulse  
Blood  
pressure  
If the irregular heartbeat symbol (  
)
)RREGULAR (EARTBEAT  
displays with your measurement results,  
we recommend you consult your  
physician. Follow the directions of your  
doctor.  
Short Long  
Pulse  
Blood  
pressure  
MOVEMENT ERROR SYMBOL (  
)
The Movement Error Symbol ( ) is displayed if you move your body during the  
measurement. Please remove the wrist cuff, and wait 2-3 minutes. Reapply the wrist  
cuff and take another measurement.  
Internationally recognized guidelines for upper limit of  
normal home blood pressure readings are as follows:  
Home Guideline for Upper Limit of Normal BP  
Systolic Blood Pressure  
Diastolic Blood Pressure  
135 mmHg  
85 mmHg  
Download from Www.Somanuals.com9. All Manuals Search And Download.  
DISPLAY SYMBOLS  
This is a general guideline because blood pressure depends on age and morbidity.  
A lower home blood pressure goal may be recommended for certain patients,  
including diabetic patients, pregnant women, and patients with renal failure.  
WARNING  
&RQWDFWꢀ\RXUꢀSK\VLFLDQꢀIRUꢀVSHFL¿FꢀLQIRUPDWLRQꢀDERXWꢀ\RXUꢀEORRGꢀSUHVVXUHꢁꢀ  
Self-diagnosis and treatment using measured results may be dangerous.  
Follow the instructions of your physician or licensed healthcare provider.  
WARNING  
DO NOT adjust medication based on measurement results from this blood  
pressure monitor. Take medication as prescribed by your physician. Only  
DꢀSK\VLFLDQꢀLVꢀTXDOL¿HGꢀWRꢀGLDJQRVHꢀDQGꢀWUHDWꢀ+LJKꢀ%ORRGꢀ3UHVVXUHꢁ  
WARNING  
The monitor is not intended to be a diagnostic device.  
 
10  
BATTERY INSTALLATION  
CAUTION  
8VHꢀRQO\ꢀꢄꢁꢅ9ꢀ³$$$´ꢀDONDOLQHꢀEDWWHULHVꢀZLWKꢀWKLVꢀGHYLFHꢁ  
1. Press the hook on the bottom of the battery cover  
and lift the cover off in the direction of the arrow.  
ꢂꢁꢀ ,QVWDOOꢀꢂꢀ³$$$´ꢀVL]HꢀEDWWHULHVꢀVRꢀWKHꢀꢆꢀꢇSRVLWLYHꢈꢀDQGꢀꢉꢀ  
(negative) polarities match the polarities of the battery  
compartment as indicated.  
3. Set the date and time.  
5HIHUꢀWRꢀ³6HWWLQJꢀWKHꢀ'DWHꢀDQGꢀ7LPH´ꢁ  
4. Replace the battery cover.  
NOTE: Make sure that the battery cover is securely in  
position.  
Download from Www.Somanuals.co1m1. All Manuals Search And Download.  
BATTERY INSTALLATION  
BATTERY REPLACEMENT  
Low Battery Indicator  
When the Low Battery Indicator appears on the display, turn the monitor off and  
remove all the batteries. Replace with 2 new batteries at the same time. Long-life  
alkaline batteries are recommended.  
WARNING  
,IꢀEDWWHU\ꢀÀXLGꢀVKRXOGꢀJHWꢀLQꢀ\RXUꢀH\HVꢃꢀLPPHGLDWHO\ꢀULQVHꢀZLWK  
plenty of clean water. Contact a physician immediately.  
NOTES:ꢀ ‡ꢀ7XUQꢀWKHꢀXQLWꢀRIIꢀEHIRUHꢀUHSODFLQJꢀWKHꢀEDWWHULHVꢁꢀ,IꢀWKHꢀEDWWHULHVꢀDUHꢀUHPRYHGꢀ  
while the unit is still on, the date and time will be reset to that of the  
previous use. The measurement results are not deleted.  
‡ꢀ:KHQꢀWKHꢀEDWWHULHVꢀDUHꢀUHSODFHGꢃꢀ\RXꢀPD\ꢀQHHGꢀWRꢀUHVHWꢀWKHꢀGDWHꢀDQGꢀWLPHꢁꢀ,Iꢀ  
WKHꢀ\HDUꢀLVꢀÀDVKLQJꢀRQꢀWKHꢀGLVSOD\ꢃꢀUHIHUꢀWRꢀ³6HWWLQJꢀWKHꢀ'DWHꢀDQGꢀ7LPH´ꢁ  
‡ꢀ7KHꢀEDWWHULHVꢀLQFOXGHGꢀZLWKꢀWKHꢀGHYLFHꢀPD\ꢀKDYHꢀDꢀVKRUWHUꢀOLIHꢁ  
CAUTION  
Dispose of the device, components and optional accessories according to  
applicable local regulations. Unlawful disposal may cause environmental  
pollution.  
 
12  
SETTING THE DATE AND TIME  
6HWꢀWKHꢀPRQLWRUꢀWRꢀWKHꢀFXUUHQWꢀGDWHꢀDQGꢀWLPHꢀEHIRUHꢀWDNLQJꢀDꢀPHDVXUHPHQWꢀIRUꢀWKHꢀ¿UVWꢀ  
time.  
1. TO START THE SETTING  
Press the Date/Time Setting button ( ) to adjust the date  
and time.  
7KHꢀ\HDUꢀÀDVKHVꢀRQꢀWKHꢀGLVSOD\ꢁ  
2. SETTING THE YEAR  
Press the Date/Time Setting button ( ) to advance by  
increments of one year.  
Press the Date/Time Setting button ( ) to set the current  
year.  
7KHꢀPRQWKꢀÀDVKHVꢀRQꢀWKHꢀGLVSOD\ꢁ  
NOTES:ꢀ ‡ꢀ7KHꢀ\HDUꢀFDQꢀEHꢀVHWꢀEHWZHHQꢀꢂꢊꢊꢋꢀDQGꢀ  
2030. When the display reaches 2030, it  
will return to 2009.  
‡ꢀ3UHVVꢀDQGꢀKROGꢀWKHꢀꢇꢀ ) button to  
increase the date and time values faster.  
3. SETTING THE MONTH  
Press the Date/Time Setting button ( ) to advance by  
increments of one month.  
Press the Date/Time Setting button ( ) to set the current  
month.  
7KHꢀGD\ꢀÀDVKHVꢀRQꢀWKHꢀGLVSOD\ꢁ  
Download from Www.Somanuals.co1m3. All Manuals Search And Download.  
SETTING THE DATE AND TIME  
4. SETTING THE DAY  
Press the Date/Time Setting button ( ) to advance by  
increments of one day.  
Press the Date/Time Setting button ( ) to set the current  
day.  
7KHꢀKRXUꢀÀDVKHVꢀRQꢀWKHꢀGLVSOD\ꢁ  
5. SETTING THE HOUR  
The time is set using AM or PM.  
Press the Date/Time Setting button ( ) to advance by  
increments of one hour.  
Press the Date/Time Setting button ( ) to set the current  
hour.  
7KHꢀPLQXWHꢀÀDVKHVꢀRQꢀWKHꢀGLVSOD\ꢁ  
6. SETTING THE MINUTE  
Press the Up button ( ) to advance by increments of one  
minute.  
Press the Date/Time Setting button ( ) to set the minute  
setting.  
7. TO TURN THE MONITOR OFF  
Press the START/STOP button.  
 
14  
SETTING THE ADVANCED POSITIONING SENSOR (APS)  
You can change the options for various settings on your monitor. Pressing the SET  
button to change a setting. Press the MEM button to select the options for that setting.  
$IWHUꢀVHOHFWLQJꢀDꢀVHWWLQJꢃꢀSUHVVꢀWKHꢀ67$57ꢌ6723ꢀEXWWRQꢀWRꢀFRQ¿UPꢀWKHꢀVHWWLQJꢀDQGꢀWXUQꢀ  
the power off.  
SETTING THE POSITIONING INDICATOR  
1. Select your User ID.  
2. Press the SET button.  
NOTE:ꢀ7KHꢀGHIDXOWꢀVHWWLQJꢀLVꢀ³RQꢄ´ꢁ  
User A  
User B  
ꢍꢁꢀ 3UHVVꢀWKHꢀ0(0ꢀEXWWRQꢀWRꢀVHOHFWꢀWKHꢀ3RVLWLRQLQJꢀLQGLFDWRUꢀ³RQꢄ´ꢃ³RQꢂ´ꢃꢀRUꢀ³R))´ꢁ  
on1: After the Positioning indicator lights in blue for more than 2 seconds, or  
in orange for more than 5 seconds, measurement starts automatically, even  
though the monitor is not in the proper position.  
on2: The Positioning indicator lights in blue for more than 2 seconds, measurement  
starts automatically.  
Measurement will not start if it lights in orange.  
oFF: Measurement starts without the Positioning indicator.  
Download from Www.Somanuals.co1m5. All Manuals Search And Download.  
SETTING THE ADVANCED POSITIONING SENSOR (APS)  
SETTING FOR RIGHT OR LEFT WRIST MEASUREMENT  
1. While in the setting mode, press the SET button until  
the wrist symbol ( or ) appears on the display.  
127(6ꢎꢀ ‡ꢀ7KHꢀGHIDXOWꢀVHWWLQJꢀLVꢀ³ ´ꢁ  
‡ꢀ$IWHUꢀ\RXꢀFKRRVHꢀ³R))´ꢀIRUꢀWKHꢀ  
Positioning indicator, the monitor skips  
this process.  
2. Press the MEM button to select the left wrist ( ) or the right wrist ( ).  
SETTING THE BUZZER  
1. While in the setting mode, press the SET button until  
the buzzer symbol ( ) appears on the display.  
NOTE:ꢀ7KHꢀGHIDXOWꢀVHWWLQJꢀLVꢀ³RQꢄ´ꢀRUꢀ³RQ´ꢃꢀ  
depending on the Positioning indicator you  
set.  
2. Press the MEM button to select the buzzer setting.  
 
16  
SETTING THE ADVANCED POSITIONING SENSOR (APS)  
,IꢀWKHꢀ3RVLWLRQLQJꢀLQGLFDWRUꢀLVꢀ³RQꢄ´ꢀRUꢀ³RQꢂ´ꢎ  
on1: The buzzer sounds only when the monitor is in proper position.  
on2: The buzzer sounds a series of two short blips if your wrist is too far away from  
the measuring position, and beeps when your wrist is in the proper position.  
oFF: The buzzer will not sound.  
,IꢀWKHꢀ3RVLWLRQLQJꢀLQGLFDWRUꢀLVꢀ³R))´ꢎ  
on: The buzzer sounds when pressing any buttons.  
oFF: The buzzer will not sound.  
RESETTING TO THE DEFAULT SETTING  
7KHꢀSRVLWLRQLQJꢀLQGLFDWRUꢀLVꢀVHWꢀ³RQꢄ´ꢃꢀWKHꢀZULVWꢀIRUꢀPHDVXUHPHQWꢀLVꢀVHWꢀ³ ´ꢃꢀDQGꢀWKHꢀ  
EX]]HUꢀLVꢀVHWꢀ³RQꢄ´ꢀDVꢀGHIDXOWꢁ  
To reset to the default setting, press and hold the SET button while in the setting mode,  
then press the START/STOP button simultaneously for more than 2 seconds.  
Download from Www.Somanuals.co1m7. All Manuals Search And Download.  
APPLYING THE WRIST CUFF  
CAUTION  
Read all of the information in the instruction manual and any other  
literature in the box before operating the unit.  
CAUTION  
This device is intended for use in measuring blood pressure and  
pulse rate in the adult population. Do not use this device on infants  
or persons who cannot express their intentions.  
APPLYING THE CUFF ON THE LEFT WRIST  
1. Roll up sleeve. Make sure your sleeve is not rolled up too  
WLJKWO\ꢀRQꢀ\RXUꢀDUPꢁꢀ7KLVꢀPD\ꢀFRQVWULFWꢀWKHꢀÀRZꢀRIꢀEORRGꢀ  
in your arm.  
2. Wrap the cuff directly against your skin.  
Do not apply over clothing. Place the cuff over your left  
wrist with your left thumb facing upward.  
3. Position the cuff leaving a clearance of approximately 1/2  
to 1 inch between the cuff and the bottom of your palm.  
4. Hold the bottom part of the cuff and wrap it around the  
ZULVWꢀVRꢀLWꢀ¿WVꢀFRPIRUWDEO\ꢀDQGꢀVHFXUHO\ꢀDURXQGꢀ\RXUꢀZULVWꢁ  
NOTE: Make sure the wrist cuff does not cover the  
protruding part of the wrist bone on the outside of  
the wrist.  
 
18  
APPLYING THE WRIST CUFF  
5. Fold the remaining part of the wrist cuff back out of the  
way.  
APPLYING THE CUFF ON THE RIGHT WRIST  
When taking a measurement using the right wrist position the  
cuff as shown in the illustration.  
5HIHUꢀWRꢀ³6HWWLQJꢀIRUꢀ5LJKWꢀRUꢀ/HIWꢀ:ULVWꢀIRUꢀ0HDVXUHPHQW´ꢁ  
Download from Www.Somanuals.co1m9. All Manuals Search And Download.  
TAKING A MEASUREMENT  
The monitor is designed to take measurements and store the measurement values in  
memory for two people using USER ID A and USER ID B. The monitor can be used to  
WDNHꢀDꢀVLQJOHꢀPHDVXUHPHQWꢀXVLQJꢀWKHꢀ*8(67ꢀPRGHꢀDUHꢀQRWꢀVWRUHGꢀLQꢀWKHꢀPHPRU\ꢁ  
ꢄꢁꢀ 6LWꢀFRPIRUWDEO\ꢀLQꢀDꢀFKDLUꢀZLWKꢀ\RXUꢀIHHWꢀÀDWꢀRQꢀWKHꢀÀRRUꢁ  
2. Select your User ID (A or B).  
User A  
User B  
3. Hold your arm across your chest at heart level.  
+ROGꢀ\RXUꢀHOERZꢀ¿UPO\ꢀWRꢀDYRLGꢀERG\ꢀPRYHPHQWꢁ  
Sit still and do not talk or move during the measurement.  
4. When arm is in correct position orange light will turn on.  
 
20  
TAKING A MEASUREMENT  
5. Press the START/STOP button.  
All symbols appear on the display.  
7KHꢀFXIIꢀVWDUWVꢀWRꢀLQÀDWHꢀDXWRPDWLFDOO\ꢁ  
$VꢀWKHꢀFXIIꢀLQÀDWHVꢃꢀWKHꢀPRQLWRUꢀDXWRPDWLFDOO\ꢀGHWHUPLQHVꢀ\RXUꢀLGHDOꢀLQÀDWLRQꢀOHYHOꢁꢀ  
7KLVꢀPRQLWRUꢀGHWHFWVꢀ\RXUꢀEORRGꢀSUHVVXUHꢀDQGꢀSXOVHꢀUDWHꢀGXULQJꢀLQÀDWLRQꢁ  
The Heartbeat Symbol ( ꢈꢀÀDVKHVꢀDWꢀHYHU\ꢀKHDUWEHDWꢁ  
Remain still and do not move until the entire measurement process is completed.  
NOTE:7RꢀVWRSꢀWKHꢀLQÀDWLRQꢀRUꢀPHDVXUHPHQWꢃꢀSXVKꢀWKHꢀ67$57ꢌ6723ꢀEXWWRQꢁꢀ7KHꢀ  
PRQLWRUꢀZLOOꢀVWRSꢀLQÀDWLQJꢃꢀVWDUWꢀGHÀDWLQJꢃꢀDQGꢀZLOOꢀWXUQꢀRIIꢁ  
5. After the monitor has detected your blood pressure  
DQGꢀSXOVHꢀUDWHꢃꢀWKHꢀFXIIꢀDXWRPDWLFDOO\ꢀGHÀDWHVꢁꢀ<RXUꢀ  
blood pressure and pulse rate are displayed.  
6. Press the START/STOP button to turn the monitor off.  
NOTE: The monitor will automatically turn off after two minutes.  
Download from Www.Somanuals.co2m1. All Manuals Search And Download.  
USING THE MEMORY FUNCTION  
Every time you complete a measurement the monitor stores the blood pressure and  
pulse rate for each user (A and B) in the memory. The monitor automatically stores up  
to 100 sets of measurement values (blood pressure and pulse rate) for each user (A and  
B). When 100 sets of measurement values are stored, the oldest record is deleted to  
save the most recent values.  
AVERAGING FUNCTION  
The monitor calculates the average reading based on up to the three most recent sets of  
measurement values taken within 10 minutes of the most recent reading.  
NOTE: If two sets of measurement values are stored in the memory for the 10 minute  
period, the average is based on the two sets of measurement values. If only  
one set of measurement values is stored, this is displayed as the average.  
TO DISPLAY THE MEASUREMENT VALUES  
1. Press the MEM button to display the average reading based on the three most recent  
sets of measurement values taken within 10 minutes of the most recent reading.  
The Average Value Symbol ( ) appears on the display when the average reading is  
shown.  
2. Press the MEM button to display the set of measurement values from the most  
recent to the oldest.  
Alternating date/time  
display  
 
22  
USING THE MEMORY FUNCTION  
NOTES:ꢀꢀ‡ꢀ7KHꢀGDWHꢀDQGꢀWLPHꢀDUHꢀDOWHUQDWHO\ꢀGLVSOD\HGꢀZLWKꢀWKHꢀPHDVXUHPHQWꢀ  
values.  
‡ꢀ3UHVVꢀWKHꢀ0(0ꢀEXWWRQꢀUHSHDWHGO\ꢀWRꢀGLVSOD\ꢀWKHꢀQH[WꢀYDOXHVꢁ  
‡ꢀ3UHVVꢀDQGꢀKROGꢀWKHꢀ0(0ꢀEXWWRQꢀWRꢀGLVSOD\ꢀWKHꢀYDOXHVꢀIDVWHUꢁ  
3. Press the START/STOP button to turn the monitor off.  
TO DELETE ALL VALUES STORED IN THE MEMORY  
The values stored in the memory are deleted by User ID. You cannot partially delete  
values stored in the memory. All values for the user you select will be deleted.  
1. Select your User ID (A or B).  
2. Press the MEM button to turn the monitor on.  
3. While holding the MEM button, press the START/STOP button down for more than  
5 seconds until the display appears as it does in the following illustration.  
4. Press the START/STOP button to turn the monitor off.  
NOTE: The monitor will automatically turn off after two minutes.  
Download from Www.Somanuals.co2m3. All Manuals Search And Download.  
CARE AND MAINTENANCE  
To keep your digital blood pressure monitor in the best condition and protect the unit  
from damage, follow the directions listed below:  
Do not forcefully bend the cuff. Do not fold tightly.  
Clean the monitor with a soft dry cloth.  
Do not use any abrasive or volatile cleaners.  
Do not attempt to clean the cuff.  
CAUTION  
Do not submerge the device or any of the components in water. Do not subject  
the monitor to extreme hot or cold temperatures, humidity or direct sunlight.  
CAUTION  
Store the device and the components in a clean, safe location.  
CAUTION  
Do not subject the monitor to strong shocks, such as dropping the unit on the  
ÀRRUꢁ  
Remove the batteries if the unit will not be used for three months or longer. Always  
replace all the batteries with new ones at the same time.  
Use the unit consistent with the instruction provided in this manual.  
Use only authorized parts and accessories.  
Use the unit in a manner consistent with the instructions provided in this manual.  
CAUTION  
Use only Omron authorized parts and accessories. Parts and accessories  
not approved for use with the device may damage the unit.  
CAUTION  
&KDQJHVꢀRUꢀPRGL¿FDWLRQꢀQRWꢀDSSURYHGꢀE\ꢀWKHꢀPDQXIDFWXUHUꢀZLOOꢀYRLGꢀWKHꢀXVHUꢀ  
warranty. Do not disassemble or attempt to repair the unit or components.  
 
24  
ERROR INDICATORS  
SYMBOL  
CAUSE  
CORRECTION  
Take another measurement and  
remain still until the measurement is  
complete.  
Monitor could not  
detect pulse wave.  
&XIIꢀXQGHUꢉLQÀDWHGꢁ  
Cuff not applied  
correctly.  
Remove the monitor from your  
wrist.  
5HDGꢀ³7DNLQJꢀDꢀ0HDVXUHPHQW´ꢁ  
Wait 2-3 minutes.  
Take another measurement.  
&XIIꢀRYHUꢉLQÀDWHGꢁ  
Device error.  
Contact Customer Service.  
Movement during  
measurement.  
Keep still and take another  
measurement.  
Remove the monitor from your  
wrist. Wait 2-3 minutes and then  
take another measurement. Repeat  
WKHꢀVWHSVꢀLQꢀVHFWLRQꢀ³$SSO\LQJꢀ  
WKHꢀ:ULVWꢀ&XIIꢁ´ꢀ,IꢀWKLVꢀV\PEROꢀ  
continues to appear, contact your  
doctor.  
Irregular or weak  
pulses are detected.  
Replace the batteries.  
5HIHUꢀWRꢀ³%DWWHU\ꢀ,QVWDOODWLRQ´ꢁ  
Batteries are worn.  
Download from Www.Somanuals.co2m5. All Manuals Search And Download.  
TROUBLESHOOTING TIPS  
PROBLEM  
CAUSES AND SOLUTIONS  
Replace both batteries with new ones at the same  
time. Check the battery installation for proper  
placement of the battery polarities.  
No power.  
No display appears on the unit.  
Blood pressure varies constantly. Many factors  
including stress, time of day, how you wrap the  
cuff, may affect your blood pressure.  
Measurement values appear too  
high or too low.  
5HYLHZꢀWKHꢀVHFWLRQVꢀ³%HIRUHꢀ7DNLQJꢀDꢀ  
0HDVXUHPHQW´ꢀDQGꢀ³7DNLQJꢀDꢀ0HDVXUHPHQW´ꢁ  
 
26  
FCC STATEMENT  
Note:  
POTENTIAL FOR RADIO/TELEVISION INTERFERENCE (for U.S.A. only)  
This product has been tested and found to comply with the limits for a Class B digital  
device, pursuant to part 15 of the FCC rules.  
These limits are designed to provide reasonable protection against harmful interference  
in a residential installation. The product generates, uses, and can radiate radio  
frequency energy and, if not installed and used in accordance with the instructions,  
may cause harmful interference to radio communications. However, there is no  
guarantee that interference will not occur in a particular installation. If the product does  
cause harmful interference to radio or television reception, which can be determined by  
turning the product on and off, the user is encouraged to try to correct the interference  
by one or more of the following measures:  
‡ꢀ5HRULHQWꢀRUꢀUHORFDWHꢀWKHꢀUHFHLYLQJꢀDQWHQQDꢁ  
‡ꢀ,QFUHDVHꢀWKHꢀVHSDUDWLRQꢀEHWZHHQꢀWKHꢀSURGXFWꢀDQGꢀWKHꢀUHFHLYHUꢁ  
‡ꢀ&RQQHFWꢀWKHꢀSURGXFWꢀLQWRꢀDQꢀRXWOHWꢀRQꢀDꢀFLUFXLWꢀGLIIHUHQWꢀIURPꢀWKDWꢀWRꢀZKLFKꢀWKHꢀ  
receiver is connected.  
‡ꢀ&RQVXOWꢀWKHꢀGHDOHUꢀRUꢀDQꢀH[SHULHQFHGꢀUDGLRꢌ79ꢀWHFKQLFLDQꢀIRUꢀKHOSꢁ  
POTENTIAL FOR RADIO/TELEVISION INTERFERENCE (for Canada only)  
This digital apparatus does not exceed the Class B limits for radio noise emissions  
from digital apparatus as set out in the interference-causing equipment standard entitled  
³'LJLWDOꢀ$SSDUDWXV´ꢃꢀ,&(6ꢉꢊꢊꢍꢀRIꢀWKHꢀ&DQDGLDQꢀ'HSDUWPHQWꢀRIꢀ&RPPXQLFDWLRQVꢁ  
Cet appareil numérique respecte les limites de bruits radioeléctriques applicables aux  
appareils numériques de Clase B prescrites dans la norme sur le materiel brouilleur:  
³$SSDUHLOVꢀ1XPpULTXHV´ꢃꢀ,&(6ꢉꢊꢊꢍꢀpGLFWpHꢀSDUꢀOHꢀPLQLVWHUꢀGHVꢀFRPPXQLFDWLRQVꢁ  
&KDQJHVꢀRUꢀPRGL¿FDWLRQVꢀQRWꢀH[SUHVVO\ꢀDSSURYHGꢀE\ꢀWKHꢀSDUW\ꢀUHVSRQVLEOHꢀIRUꢀ  
compliance could void the user’s authority to operate the equipment.  
Download from Www.Somanuals.co2m7. All Manuals Search And Download.  
LIMITED WARRANTY  
Your BP652 IntelliSense® Automatic Wrist Blood Pressure Monitor, excluding  
the wrist cuff and batteries, is warranted to be free from defects in materials and  
workmanship appearing within 5 years from the date of purchase, when used in  
accordance with the instructions provided with the monitor. The above warranties  
extend only to the original retail purchaser.  
We will, at our option, repair or replace without charge any monitor or wrist cuff  
covered by the above warranties. Repair or replacement is our only responsibility and  
your only remedy under the above warranties.  
To obtain warranty service contact Customer Service by calling 1-800-634-4350 for the  
address of the repair location and the return shipping and handling fee.  
Enclose the Proof of Purchase. Include a letter, with your name, address, phone  
QXPEHUꢃꢀDQGꢀGHVFULSWLRQꢀRIꢀWKHꢀVSHFL¿FꢀSUREOHPꢁꢀ3DFNꢀWKHꢀSURGXFWꢀFDUHIXOO\ꢀWRꢀSUHYHQWꢀ  
damage in transit. Because of possible loss in transit, we recommend insuring the  
product with return receipt requested.  
THE FOREGOING IS THE SOLE WARRANTY PROVIDED BY OMRON IN  
CONNECTION WITH THIS PRODUCT, AND OMRON HEREBY DISCLAIMS  
ANY OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING  
IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A  
PARTICULAR PURPOSE. IMPLIED WARRANTIES AND OTHER TERMS  
THAT MAY BE IMPOSED BY LAW, IF ANY, ARE LIMITED IN DURATION  
TO THE PERIOD OF THE ABOVE EXPRESS WARRANTY.  
OMRON SHALL NOT BE LIABLE FOR LOSS OF USE OR ANY OTHER  
SPECIAL, INCIDENTAL, CONSEQUENTAIL OR INDIRECT COSTS,  
EXPENSES OR DAMAGES.  
7KLVꢀZDUUDQW\ꢀSURYLGHVꢀ\RXꢀZLWKꢀVSHFL¿FꢀOHJDOꢀULJKWVꢃꢀDQGꢀ\RXꢀPD\ꢀKDYHꢀRWKHUꢀULJKWVꢀ  
that vary by jurisdiction. Because of special local requirements, some of the above  
limitations and exclusions may not apply to you.  
FOR CUSTOMER SERVICE  
Visit our web site at:  
Call toll free:  
1-800-634-4350  
 
28  
SPECIFICATIONS  
BP652 (HEM-6052-Z)  
Model:  
LCD Digital Display  
Display:  
Pressure: 0 to 299 mmHg, Pulse: 40 to 180/min.  
Measurement Range:  
Accuracy/Calibration:  
Pressure: ±3mmHg or 2% of reading  
Pulse: ±5% of reading  
Automatic by electric pump  
Inflation:  
Automatic pressure release valve  
Automatic exhaust valve  
Deflation:  
Rapid Air Release:  
Measurement Method:  
Power Source:  
Battery Life:  
Oscillometric method  
ꢄꢁꢅ9ꢀꢂꢀ³$$$´ꢀEDWWHULHV  
Approx. 300 uses with 2 new alkaline batteries  
50ºF to 104ºF (10ºC to 40ºC) /15 to 90% RH  
Operating Temperature  
/Humidity:  
-4ºF to 140ºF (-20ºC to 60ºC) /10 to 95% RH  
700-1060 hPa  
Storage Temperature /  
Humidity/Air Pressure:  
Approximately 4 oz. (114g)  
not including batteries  
Main Unit Weight:  
$SSUR[ꢁꢀꢂꢀꢍꢌꢏ´ꢇOꢈꢀîꢀꢂꢀꢍꢌꢏ´ꢇZꢈꢀîꢀꢐꢌꢑ´ꢀꢇKꢈ  
Main Unit Dimensions:  
ꢇꢐꢊꢀPPꢀîꢀꢐꢊꢀPPꢀîꢀꢂꢄꢀPPꢈꢀꢇQRWꢀLQFOXGLQJꢀWKHꢀZULVWꢀFXIIꢈ  
$SSUR[LPDWHO\ꢀꢅꢀꢄꢌꢏ´ꢀWRꢀꢑꢀꢄꢌꢂ´ꢀꢇꢄꢍꢁꢅꢀWRꢀꢂꢄꢁꢅꢀFPꢈ  
Measurable circumfer-  
ence of wrist:  
Up to 100 readings per user  
Memory:  
Contents:  
0DLQꢀ8QLWꢃꢀ6WRUDJHꢀ&DVHꢃꢀꢂꢀ³$$$´ꢀ$ONDOLQHꢀ%DWWHULHVꢃꢀ  
,QVWUXFWLRQꢀ0DQXDOꢃꢀDQGꢀ4XLFNꢀ6WDUWꢀ*XLGH  
127(ꢀꢁ7KHVHꢁVSHFL¿FDWLRQVꢁDUHꢁVXEMHFWꢁWRꢁFKDQJHꢁZLWKRXWꢁQRWLFHꢂ  
Download from Www.Somanuals.co2m9. All Manuals Search And Download.  
Omron Healthcare, Inc.  
1200 Lakeside Drive  
Bannockburn, IL 60015  
Copyright © 2010 Omron Healthcare, Inc.  
Made in China  
5329415-9A  
 

Miele Freezer 07 682 190 User Manual
Miller Electric Welding System HJ134589 User Manual
Multi Tech Equipment Trash Compactor MVH306DS2 User Manual
Niles Audio Home Theater System iC2 User Manual
Nilfisk ALTO Vacuum Cleaner SR 1000S B User Manual
Nortel Networks Telephone i2021 Series User Manual
Olympus Microphone dr2000 User Manual
Onkyo Stereo System HT S3300 User Manual
Panasonic Air Compressor DD66C12GBU6 User Manual
Panasonic Drill EY7411 User Manual