Omnitron Systems Technology Network Card 10AUI T User Manual |
Power Adapter Notice:
Switch Settings:
1. When using in a stand-alone configuration, this
product can be powered from the AUI port and does
not require an external power source.
2. If the AUI port is not capable of providing power to
the FlexPoint 10AUI/T and when using in a stand-
alone configuration, this product is intended to be
and must be used only with a Listed Direct Plug-In
Power Unit marked “Class 2” and rated at 9Vdc, 1
Amp.
“RJ45 Cross-Over” Switch: When connecting the UTP to a
hub or switch, set switch to “Straight-Through” (factory
setting). When connecting to a workstation, set it to “Cross-
Over.”
FlexPointTM 10AUI/T User Instructions
Description:
“SQE” switch: When attaching to a PC (or a workstation),
the SQE switch should be set to “SQE Enable” (factory
setting). When connecting to a hub or a switch, it should
be set to “SQE Disable.”
The FlexPointTM 10AUI/T transceiver is an IEEE 802.3
compatible Ethernet unshielded twisted pair (UTP) trans-
ceiver that provides physical medium connection to devices
featuring Attachment Unit Interface (AUI) connectors. It
can be powered from theAUI connector, an externalAC
or 48VDC power adapter or a 14-unit Powered Chassis.
“UTP Range” switch: Set this switch according to the
required distance of the UTP connection. For normal
operation, set it to ”100m” (factory setting). When distance
of over 100m is required, set it to “>100m”.
3. When using an external power source, this product
should always be used only with Omnitron Supplied
Power Unit model number 9113-PS.
The FlexPoint 10AUI/T has a 15-pin AUI connector that
attaches to a mating AUI connector mounted on hosting
Ethernet DTE equipment such as a workstation or a PC,
or on a repeater such as a hub or a switch.
WARNING!
Note that when used in the “>100m” mode, the sensitivity
of the FlexPoint 10AUI/T is increased making it more
sensitive both to signal and noise, so this mode should
be used with caution when the distance requires it.
Before inserting the Power Adapter, verify
that the power on the unit is appropriate
for your AC line voltage source.
This FlexPoint 10AUI/T model is described here:
Model Maximum Distance
LED Indicators:
4321 100 meters
Mounting and Cable Attachment:
LED
Power
AUI-Rx
UTP-Link/Rx Green
Collision/
Jabber
Color
Yellow
Green
Description
Power applied
Host Data Received
UTP Link / Data Received
Operating in Half-Duplex, the FlexPoint 10AUI/T fea-
tures a switch selectable SQE test function that pro-
vides diagnostic information to the hosting station. It also
provides LED status about network conditions that assist
in network installation and maintenance.
The FlexPoint 10AUI/T can be mounted using a wall-
mounting kit. It can also be rack-mounted using a
5-Module shelf or a high-density 14-unit FlexPoint
Powered Chassis.
Connect the FlexPoint 10AUI/T to the 15-pin AUI port
on a PC, workstation, hub or switch; slide the connector
latch locking it into place. The AUI cable is limited to 50
meters . Attach a UTP category 3 or higher cable to
the RJ45 connector. Note that the total length of the
cable should not exceed 100 meters.
Yellow
Collision or Jabber Detected
The 4321 model can be used stand-alone, wall-mounted,
rack-mounted on a 5-unit shelf or in a 14-unit AC or
48VDC Powered Chassis.
Technical Support:
For help with this product, contact our Tech. Support:
Limitation of Warranty
Warning
The foregoing warranty shall not apply to defects
resulting from improper or inadequate use and/or
maintenance of the equipment by Buyer, Buyer-supplied
equipment, Buyer-supplied interfacing, unauthorized
modifications or tampering with equipment (including
removal of equipment cover by personnel not
specifically authorized and certified by Omnitron), or
misuse, or operating outside the environmental
specification of the product (including but not limited to
voltage, ambient temperature, radiation, unusual dust,
etc.), or improper site preparation or maintenance.
The operating description in this Instruction Manual is
for use by qualified personnel only. To avoid electrical
shock, do not perform any servicing of this unit other
than that contained in the operating instructions, unless
you are qualified and certified to do so by Omnitron
Systems Technology, Inc.
Phone:
Fax:
(949) 250-6510
(949) 250-6514
Address: Omnitron Systems Technology, Inc.
140 Technology Drive, #500
Caution
Irvine, CA 92618 USA
All user-required operations can be performed without
opening the unit. Never attempt to open or remove the
cover or tamper with the unit.
E-mail:
URL:
Warranty
No other warranty is expressed or implied. Omnitron
specifically disclaims the implied warranties of
merchantability and fitness for any particular purpose.
This product is warranted to the original purchaser against
defects in material and workmanship for a period of TWO
YEARS from the date of shipment. A LIFETIME warranty
maybeobtainedbytheoriginalpurchaserbyREGISTERING
this product with Omnitron within 90 days from the date of
shipment. TO REGISTER, COMPLETEAND MAILOR FAX
THE REGISTRATION PORTION OFTHIS INSTRUCTION
MANUAL TO THE INDICATED ADDRESS. Or you may
register your product on the internet at http://
Omnitron will, at its option, repair or replace a product which
is proven to be defective.
Exclusive Remedies
The remedies provided herein are the Buyer’s sole and
exclusive remedies. Omnitron shall not be liable for any
direct, indirect, special, incidental, or consequential
damages, whether based on contract, tort, or any legal
theory.
Forwarrantyservice, theproductmustbesenttoanOmnitron
designated facility, at Buyer’s expense. Omnitron will paythe
shipping charge to return the product to Buyer’s designated
US address using Omnitron’s standard shipping method.
Form: 040-04321-001C 11/07
|