Nortel Networks Telephone M7310 User Manual

Return  
to Menu  
• • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • •  
Norstar ICS  
Hospitality Features Card  
• • • • • • • • • • • • • • • • • •  
 
≤°‡fi  
Cancel ≤£°‡fi  
Alarm time  
The Alarm time feature provides an alarm clock capability on system set and  
analog telephones connected to anATA or an ASM. Both room sets and common  
sets can be programmed to sound an audible alert at a requested time.  
One Alarm time within a 24 hour period is programmable on a room or common  
set and must be reset daily. When the alarm sounds, all sets in a given room alert.  
Canceling the alarm on any set cancels the alarm on all the sets in the room. A  
new Alarm time entered on a room or common set overwrites any alarm set  
previously.  
To program the Alarm time feature on an system telephone:  
1. Press ≤°‡fi. The display shows Alrm: 07:00am OFF.  
If the alarm time is correct press ON/Oꢀ. The display shows Alrm:07:00am ON.  
Press DONE to exit.  
or  
To enter a new alarm time press CHG. The display shows Enter time:.  
Enter a new 4 digit alarm time.  
If the 24 hour clock format is used (hour: 00 to 23 and minutes: 00 to 59), no  
confirmation is required. The display shows Alarm ON hh:mm .  
If the 12 hour format is used, the display shows hh:mm AM or PM?. Press the AM or  
PM display key. The display shows Alarm ON hh:mm .  
Alarm time:  
To program the Alarm time feature on an analog telephone:  
analog phone  
1. Press û¥¡àÞ. A tone sounds.  
2. Enter a 4 digit alarm time.  
If the 24 hour clock format is used (hour: 00 to 23 and minutes: 00 to 59), a tone  
sounds.  
If the 12 hour format is used, press to select am or £ to select pm. A tone  
sounds.  
At the selected times, sets in the room ring to wake-up or remind the occupant of  
the next event or meeting.  
Cancel the  
alarm  
To cancel the Alarm time on a system telephone, press ≤£°‡fi.  
The display shows Alarm Oꢀ.  
To cancel the Alarm time on an analog telephone pressû£¡àÞ.  
Turn off  
the alarm  
When a set rings at the selected time, the occupant can release the Alarm ring as  
follows:  
On a system telephone, press any button except the button.  
On an analog telephone lift and replace the handset back into position.  
 
≤°‡‡  
Alarm time:  
HS admin set  
Only an HS admin set can use the Hospitality Services admin alarm feature. The  
HS admin alarm feature is room oriented only, it does not control the alarms on  
common sets.  
The HS admin alarm feature can:  
query the current or last alarm time set for a room  
overwrite previous Alarm time programming for a room on the system  
assign an Alarm time for any room on the system  
change an Alarm time for any room on the system  
cancel an Alarm pending for any room on the system  
To program the Alarm time for a room with the HS admin alarm feature:  
1. Press ≤°‡‡ on a two-line display system telephone.  
2. If configured, the display shows Password:. Enter the Desk admin password.  
3. The display shows Al of rm#:. Enter the room number.  
4. Press VIEW. The display shows Alrm: 07:00am Oꢀꢀ:. If the alarm time is correct  
press the ON/Oꢀꢀ display key to activate the alarm.  
5. Enter a four digit alarm time.  
If the 24 hour format is used (hour: 00 to 23 and minutes: 00 to 59), no  
confirmation is required. The display shows Alarm hh:mm ON.  
If the 12 hour format is used, the display shows the four digit time plus AM or PM?.  
Press the AM or PM display key. The display shows Alarm hh:mm am or pm ON.  
6. Press the ® button to exit programming.  
Room set ≤°‡fl  
HS admin set ≤°‡°  
Room  
condition  
The Room condition (RC) feature allows users to exchange information about the  
serviced state of a room. The RC feature is available from a room set or an HS  
admin set.  
Room sets can:  
set the associated room’s state to Service done (Srvc done)  
set the associated room’s state to Needs service (Needs srvc)  
query the state of the associated room on a set with a display.  
HS admin sets can:  
set any room’s state to Service done (Srvc done)  
set any room’s state to Needs service (Needs srvc)  
query the state of any room.  
The system changes the state of occupied rooms to Needs service on a daily  
basis at a set time as configured in the system.  
Maintenance personnel program the condition of the room to Service done when  
service in the room is complete.  
The front desk attendant can query or program the condition of a room with an HS  
admin set. The system automatically assigns the status of a room to Needs srvc,  
when a Room occupancy status changes from occupied to Vacant.  
 
To update the Room condition using a room set:  
Room  
condition:  
Room set  
1. Press ≤°‡fl on a system telephone or press û¥¡àß on  
an analog telephone.  
2. At the prompt, enter the status of the room.  
3. Press on the dial pad to indicate Set to srv done. If required, enter the  
Room condition password.  
or,  
Press ¤ on the dial pad to indicate Set to needs srv. If required, enter the  
Room condition password.  
4. The display shows Set to srv done or Set to needs srv.  
To update or query the Room condition using an HS admin set:  
Room  
condition:  
HS admin set  
1. Press ≤°‡° on a two-line display system telephone.  
2. If configured, the display shows Password:. Enter the Desk admin password.  
3. The display shows Cd of rm#:. Enter the room number and press OK.  
4. The display shows rrrrr:Vacant. Press the CHANGE display key and select the  
required status for the room set: if the room is occupied, select Srvc done or  
Needs srvc; if the room is vacant, select Vacant or Needs srvc.  
The default setting is Vacant.  
5. To update or query other room sets, press the ꢀIND or NEXT display key and  
return to step 3. If there are no more room sets updates or queries, press the  
® button to exit programming.  
≤°‡·  
Room  
occupancy  
The Room occupancy (RO) feature allows front desk operators to assign dialing  
restrictions to room sets, and also works with the Room condition (RC) feature.  
Dialing restrictions for room sets are defined in system programming. The RO  
feature does not apply to common sets.  
To access the Room Occupancy feature and assign the state of a room set:  
1. Press ≤°‡· on a two-line display system telephone.  
2. If configured, the display shows Password:. Enter the Desk admin password.  
3. The display shows Oc of rm#:. Enter the room number and press OK.  
4. The display shows rrrrr:Vacant. Press the CHANGE display key and select the  
required status for the room set: Vacant, Basic, Mid or Full. The default setting  
is Vacant.  
5. To program other rooms, press the ꢀIND or NEXT display key and return to step  
3. If no more rooms require programming, press the ® button to exit  
programming.  
Programming a room to Vacant state cancels any outstanding alarms.  
Hospitality  
passwords  
The Hospitality Services feature allows for two types of passwords to access  
different areas of Hospitality programming.  
The Desk password is used to access all Hospitality Services admin features.  
The Room condition password controls the ability to change the room  
condition.  
Default passwords are created and changed in system programming.  
 
Meridian and Norstar are trademarks of Nortel Networks.  
Meridian Norstar is manufactured by Nortel Networks.  
P0941572 Issue 01  
Printed in Canada  
• • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • •  
 

Milan Technology Network Card MIL C2113 User Manual
Milwaukee Caulking Gun 6560 Series User Manual
Multiquip Webcam b46s90 User Manual
NEC IP Phone IP3AT 8WVAUSTRALIA User Manual
NETGEAR Switch FS750T2NA User Manual
Newcon Optik Hunting Equipment LRM 220SI User Manual
Onkyo Stereo System TX DS898 User Manual
OPTI UPS Power Supply FS600 FS600B User Manual
Panasonic Camera Accessories AWRP120GJ User Manual
Panasonic Karaoke Machine 32 1158 User Manual