Material List Q-1300/Q-1800 Ice Machines:  
Quantity  
1
1
Armaflex Insulation  
Armaflex Insulation  
6’ x 2” ID x 3/8” wall thickness  
6’ x 3/4” ID x 3/8” wall  
(used on evaporator inlet/outlet and dump valve drain line)  
1
1
2
2
1
1
1
4
1
1
1
1
Bulkhead Insulation Back  
Bulkhead Insulation Back  
Side Wall Insulation  
Bulkhead Corner Insulation Cover  
Bulkhead Insulation (behind dump valve) 3 3/8” x 5 5/8” x 3/8”  
Vacuum Formed Base with Insulation  
Foam Gasket For Top Edge of Bin  
Evaporator Inlet/Outlet Insulation  
Tube Silicone Sealant Black  
Tube Silicone Sealant White 3 oz  
Mylar Strip  
9” x 48” x 3/4”  
3” x 48” x 3/8”  
9” x 10” x 3/8”  
6” x 1” x 3/8”  
12 3/4” x 48” x 3/4”  
2’ x 3/4” x 1/4”  
3” x 3” x 3/8”  
Used to seal base/bulkhead insulation  
Used to seal front edge of vacuum-formed base  
5” x 42”  
Double Face Tape  
Additional materials required: caulk gun, 2” x 4’ wood blocks, wire ties.  
Preparation  
1. Disconnect power from ice machine.  
2. Remove front, top, and side panels.  
3. Drain water from sump trough.  
4. Ice machine must be thoroughly dried before the insulation can be installed. Use towels to dry bulkhead and base assembly.  
Base Insulation Installation  
1. Raise the ice machine above the bin. A high lift can be used or (two people required) lift front edge of ice machine and place  
wood blocks (2”x4”) between ice machine and bin. Lifting one side of ice machine at a time, move wood blocks to center  
balance point of ice machine.  
2. Slide vacuum formed base insulation assembly between the ice machine and bin. Align the insulation with the back and sides of  
the bin and ice machine.  
3. Add one layer of foam tape insulation from the front of the bin to the front of the base insulation on the left and right side.  
2. Install vacuum-formed base  
insulation and align back and sides.  
3. Add foam tape both sides.  
Manitowoc Ice, Inc.  
2110 South 26 Street, P.O. Box 1720, Manitowoc, WI 54221-1720 USA  
Telephone 920-682-0161, Fax - Sales: 920-683-7589, Service/Parts: 920-683-7585, Other: 920-683-7879  
8005483  
Sheet 1 of 3  
06/02/00  
 
9. Install additional insulation on entire suction  
line  
5. Install 3” x 3” insulation on  
Q1300/Q1800  
4. Apply bead of silicone before applying insulation  
5. Align insulation slits with base ribbing  
7. Seal insulation to base with silicone sealant  
10. Insulate drain line  
5. When installing in limited access areas, the insulation can be cut at the right TXV to allow installation of the bulkhead  
insulation in two pieces. Peel the white backing off of the insulation for the back bulkhead (9” x 48”). Align the slots in the  
insulation with the ridges in the base. Press the insulation against the bulkhead to secure. The insulation will overlap the left  
and right side insulation installed earlier. Position 3” x 3” square insulation on back bulkhead insulation, around the evaporator  
inlet and outlet tubing (four pieces total).  
6. Peel the white backing off of the 3” x 48” strip of insulation and install over the bottom section of the 9” x 48” insulation  
installed in step 5. Align cut slots with the back bulkhead insulation and press to seal.  
7. Use black silicone sealant to seal: insulation to the base, foam insulation to foam insulation joints, any voids where insulation  
meets or overlaps. Add bulkhead corner insulation covers where the rear bulkhead and side panel corners meet.  
8. Verify no moisture is present in the suction line tubing. If moisture is present, drain and dry the insulation and reinstall.  
9. Install armaflex insulation over the existing insulation on suction line. Use 3/4” x 3/8” insulation on the evaporator outlet and  
inlet tubing and 2” x 3/8” on the rest of the suction line. Use suitable glue to seal insulation airtight (do not use electrical tape).  
Seal the ends of the insulation with wire ties.  
10. Remove clear vinyl tube from dump valve and brass wing adapter. Install armaflex insulation over tube and then reinstall tube  
to dump valve and adapter. Ensure white clamps are secure to prevent water from leaking.  
8005483  
Sheet 3 of 3  
06/02/00  
 

Lennox International Inc Humidifier 2 4SA13 User Manual
Lenovo Switch H415 User Manual
LG Electronics Cell Phone VX4700 User Manual
Life Fitness Bicycle LC 6500N User Manual
Lucent Technologies Telephone 555 230 796 User Manual
Marshall Amplification Stereo Amplifier JCM800 Series User Manual
Maytag Range W10252706B User Manual
McCulloch Brush Cutter 115154526 User Manual
Melissa Hair Dryer 235 028 User Manual
Melissa Microwave Oven 653064 User Manual