J/B/G-0600 COMPRESSOR REPLACEMENT
Installation Instructions
NOTE: THIS REPLACEMENT IS ONLY FOR THE J, B, AND G-SERIES ICE MACHINES. START AND RUN
COMPONENT CHANGES VARY WITH THE TYPE OF MACHINE. FOR J-SERIES MACHINES ONLY, THE
RUN CAPACITOR NEEDS TO BE REPLACED WITH THE ONE INCLUDED IN THE KIT. B AND G-SERIES
MACHINES NEED ALL OF THE START AND RUN COMPONENTS REPLACED WITH THE ONES
INCLUDED IN THE KIT.
1. Disconnect power to the ice machine at the electrical
disconnect (moving the toggle switch to the off
position will not disconnect line voltage).
2. Remove panels (top, front, left and right sides).
3. Recover refrigerant from ice machine.
6. Unsweat suction line at compressor port. Unsweat
discharge and process lines at the T fitting and
swage joint (or after “T” fitting, if remote)
respectively.
NOTE: IF REPLACING COMPRESSOR IN
A
4. Remove right side corner post (when facing the front
of the machine) and back panel.
REMOTE ICE MACHINE, BE SURE TO
UNSWEAT THE CONNECTION BETWEEN
THE HPR VALVE AND THE PROCESS
TUBING AT THE “T” FITTING.
Swage Joint
“T” Fitting
5. Remove wiring from compressor terminals.
7. Remove compressor from machine. Make sure to
crimp and braze shut ports to compressor.
8. Insert new compressor into the machine, as shown.
Manitowoc Ice, Inc.
2110 South 26 Street, P.O. Box 1720, Manitowoc, WI 54221-1720 USA
8006183
Telephone 920-682-0161, Fax - Sales: 920-683-7589, Service/Parts: 920-683-7585, Other: 920-683-7879
Sheet 1 of 3
Web Site - www.manitowocice.com
06/25/01
17. Make sure that all the tubing is not rubbing against
anything else in the machine.
18. Reinstall the corner post that was removed earlier
and place electrical cover on compressor.
19. Reinstall back panels of ice machine.
20. Make sure to replace start and run components
according to the machine you are replacing the
compressor in. See note in the beginning of
instructions for designation.
21. Reinstall all other panels.
22. Reconnect power and test run ice machine.
8006183
Sheet 3 of 3