Calculite® HID Adjustable Accent C7P38MHA
Page 1 of 3
7" Aperture, PAR38 Ceramic Metal Halide
C7P38
20" (508 mm) to
30" (762 mm)
1
5
8
1
3
4
2
9
6
7
10-5/8"
(270 mm)
20-1/4" (514 mm)
Top View
(Electronic Ballast)
20" (508 mm) to
30" (762 mm)
11 7/8"
(302 mm)
Vertical Adjustment:
3/4" (25 mm) to
2 7/8" (73 mm)
10-5/8"
(270 mm)
22-1/8" (562 mm)
Top View
(Magnetic Ballast)
7" (178 mm) Dia.
1 1/8" (29 mm) max.
Ceiling Thickness
5/8" (16 mm)
8-3/8" (213 mm) Dia.
Ceiling Cutout: 8” (203mm) Dia.
Reflector Trim
C7P38MHA CLW
Frame-In Kit
Lamp (Ceramic MH)
Specular Clear, White Painted Flange.
Specular Clear, Matching Flange.
C7A70P38E1 Electronic 120V / C7A70P38E2 Electronic 277V 70W PAR38
C7A10P38E1 Electronic 120V / C7A10P38E2 Electronic 277V 100W PAR38
C7A15P38E1 Electronic 120V / C7A15P38E2 Electronic 277V 150W PAR38
CLP
CCDW Comfort Clear Diffuse, White Painted Flange.
CCDP
CCZW
CCZP
Comfort Clear Diffuse, Matching Flange.
Champagne Bronze, White Painted Flange.
Champagne Bronze, Matching Flange.
C7A70P38U Magnetic 120V/277V
C7A10P38U Magnetic 120V/277V
C7A15P38U Magnetic 120V/277V
70W PAR38
100W PAR38
150W PAR38
Features
Electrical (cont.)
Ballast ANSI Code Voltage
Max. Amps
Input Watts
78
110
167
1. Reflector Trim: Low brightness,anodized aluminum with integral flange in
painted white or polished to match inside of cone.
70W MH M98/M143
100W MH M90/M140
150MWH M102
120/277
120/277
120/277
0.67/0.28
0.90/0.43
1.40/0.61
2. Lamp Holder Assembly: Unitized optics insure alignment of lamp and aper-
ture cone. Integral C-shaped media holder accepts up to two 4 3/4" media.
3. Trim Adjustment Mechanism: Provides 45° vertical tilt, 360°+ horizontal
rotation; lockable. Patented EZ-Aim Helical Drive System provides fast and
accurate hot aiming with Philips screwdriver.
Magnetic Ballast: 120/277V dual voltage, 60 Hz., encased and potted,
HX-HPF circuit type, high power factor, sound rating “B”, -20° F minimum
starting temperature, Type 1 Outdoor rating.
4. Socket: Medium base porcelain socket with nickel plated screwshell,
pulse rated.
Ballast ANSI Code Voltage
Max. Amps
1.90/0.80
2.40/1.10
3.70/1.60
Input Watts
94
125
180
70W MH M98/M143
100W MH M90/M140
150W MH M102
120/277
120/277
120/277
5. Frame Housing: Steel, 0.029" (22-Ga.), matte black finish.
6. Frame Vertical Adjustment Mechanism: Accommodates mounting to vir-
tually any ceiling system using pre-installed mounting bars, or 1/2" EMT tub-
ing (by others). Single locking feature secures all adjustments. Alignment
holes and markings allow fixture to be pre-set prior to installation. Final
adjustment can be made from below from inside fixture.
Options and Accessories
Fuse (magnetic ballast): Add suffix F1 or F2 to Frame-In Kit (F1=120V, F2=277V).
7. Mounting Bars: Galvanized steel, 0.048" (18-ga.), pre-installed telescoping
bars extend to 30" long and lock securely into position. Built-in locking tabs
provide positive attachment to common T-bar systems. Self-centering feature
simplifies installation in 24" O.C. grid systems. Attaches to steel or wood
joists without accessories.
8. Retention Springs: Rust resistant springs secure trim for quick, tool-less
installation.
9. Ballast / Cover Assembly: Accessible from below and removable without
tools for inspection and ballast replacement .
10. Junction Box: 0.059" (16-ga.) galvanized steel. UL listed for 8 No. 12 AWG,
90°C through branch circuit conductors. Allows inspection from below.
11. Thermal Protector: (Not Shown) Meets NEC and UL requirements. Do not
install insulation above nor within 3" (76mm) of any part of the luminaire.
Chicago Plenum: Consult Factory.
Labels: UL (Suitable For Damp Locations), CSA (magnetic ballast only), I.B.E.W.
For 150W, install fixtures with minimum spacing: 2 feet from center-to-center
of adjacent luminaries; 1/2 inch from top of luminaire to overhead building member;
1 foot from luminaire center to side building member.
Job Information
Type:
Job Name:
Cat. No.:
Lamp(s):
Notes:
Electrical
Electronic Ballast: 120V or 277V, 50/60 Hz., encased, high power factor, T.H.D.
<15%, thermally and transient protected, RMI/RFI complies with FCC part 18
non-consumer limits, shut-down circuit at end of lamp life, sound rating "A",
-5° F minimum starting temperature, Type 1 Outdoor rating.
Lightolier a Genlyte Thomas Company
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
© 2004 Genlyte Thomas Group LLC (Lightolier Division) • A0504
|