LST Network Card LIF64 1 User Manual

Loop Interface  
LIF64-1  
• Intelligent analogue ringbus  
technology  
• Up to 99 detectors and 99 modules  
with System Sensor/200 protocol  
• Up to 126 detectors or modules with  
Apollo/Discovery protocol  
• Easy setup of loop elements thanks  
to AUTO configuration  
• Maintenance prognosis for smoke  
detectors  
Description  
The Loop Interface LIF64-1 allows for the connection of Thanks to the ring-shaped cabling, all elements on the  
one ADM loop with bi-directional data exchange and up loop remain functional in the event of a single wire brea-  
to 128 detector zones to fire detection control panels kage. In addition, the wire breakage is displayed on the  
Series BC216. The ADM loop supports 198 elements control panel. What is more, the operational reliability of  
(99 detectors and 99 modules) with System Sen- those parts of the loop that are not affected is secured  
sor/200 protocol or 126 elements (detectors and/or in the event of a short circuit. Unshielded wires can be  
modules) with Apollo/Discovery protocol.  
used for the fire detector cabling and, therefore, exis-  
ting installations can be assumed smoothly and existing  
Each ADM loop can be subdivided into a maximum of cabling can be reused.  
128 detector zones. The function of the detector zone  
(automatic fire detector zone, technical message, fault On the control panel, you can perform a maintenance  
detection zone, etc.) as well as the element type (e.g., prognosis for each connected smoke detector. The  
automatic detector, manual call point, monitor module, continuous monitoring of the detector function allows  
control module or conventional zone module) can be for cost-optimized operation and optimum planning of  
parameterised on the fire detection control panel.  
the maintenance works.  
A two-sided isolator is integrated on the Loop Interface The Loop Interface provides a processor of its own. At  
(at the beginning and the end of the loop). The loop a possible central processing board failure, the diver-  
wiring can be realized as ring, branch or any given com- sified redundancy concept thus ensures reliable alarm  
bination of sectional rings and branches.  
recognition.  
Building Safety. Building Security.  
A
© LABOR STRAUSS SICHERUNGSANLAGENBAU GMBH • A-1231 WIEN • WIEGELESTRASSE 36 • TEL +43 1 52114-0 • FAX +43 1 52114-27  
LIF64-1_DBL_LST_EN_0804.PDF • PAGE 1  
[email protected] • WWW.LST.AT • ALL RIGHTS RESERVED  
 

Land Pride Lawn Mower 357 187M User Manual
Life Fitness Home Gym FZPEC User Manual
Lightolier Work Light QVS2GPTOS2FT User Manual
Lucent Technologies Speaker 585 210 940 User Manual
Magnadyne Car Stereo System MV PI300A User Manual
Magnavox TV VCR Combo 27MDTR20s User Manual
M Audio Computer Hardware Revolution 71 User Manual
M Audio DJ Equipment VCS3008BI User Manual
Maytag Washer W10353871A User Manual
Micro Innovations Speaker MM610D User Manual